Performance Chart

Installation Procedure

To  assure  maximum  performance  from  your  690  Series  Rotary
Sprinklers, read these instructions completely prior to installing or
servicing the sprinkler.

Construct Swing Joints

1. Construct  triple  swing  joints  for  each  sprinkler  as  shown  in

Figure 1. Use PVC  or ABS pipe nipple for sprinkler connection.

Note: On sites where the possibility of heavy equipment
rolling over a sprinkler exists, the swing joint will flex
preventing damage to the lateral or main lines. On a new
installation in raw ground where the sprinklers are to be
initially installed above the finished grade and lowered when
new turf is established, the swing joint allows sprinkler
repositioning without changing risers. This is a common and
practical procedure which eliminates the problem of dirt
being accidentally introduced into the lateral lines when a
riser is changed.

2. Flush lines thoroughly prior to installing sprinkler.

3. Apply Teflon tape on riser threads. Install sprinkler to riser

and tighten.

CAUTION

Use only Teflon™ tape on riser threads. Use of pipe dope or other types of sealing compounds can
cause deterioration of sprinkler body threads.

Figure 1

Triple Swing Joints

Base

Nozzle Set

Nozzle Set

Nozzle Set

Pressure

-90

-91

-92

Size 3/8 in.

Size 7/16 in.

Size 1/2 in.

PSI

Rad.

GPM

Rad.

GPM

Rad.

GPM

40

50

60

78 ft.

45.1

87 ft. 

53.7

70

82 ft.

48.6

91 ft. 

57.2

96 ft.

67.5

80

87 ft.

51.0

96 ft.

61.2

100 ft.

74.0

90

89 ft.

54.1

98 ft.

67.3

105 ft.

78.0

100

90 ft.

57.1

100 ft.

73.4

108 ft.

82.2

MODEL NUMBER CODE

69X-XX-XX

Arc

Cover

Operation

Nozzle Set

1 = Quarter Circle

0 = Standard

1 = Valve-in-head

-90 = 3/8 in.

2 = Half Circle

Hydraulic N.O.

-91 = 7/16 in.

Regular Speed

2 = Checkomatic

-92 = 1/2 in.

4 = Full Circle

6 = Valve in head

6 = Two Speed

electronic

60°-180°

8 = Two Speed

180°

Spacing of Sprinklers

Square Spacing

No Wind

55% of diameter

4 m.p.h.

50% of diameter

8 m.p.h.

45% of diameter

Triangular Spacing

No Wind

60% of diameter

4 m.p.h.

55% of diameter

8 m.p.h.

50% of diameter

Single Row Spacing

No Wind

50% of diameter

4 m.p.h.

50% of diameter

8 m.p.h.

45% of diameter

Conversion Information

• All gallons per minute shown are U.S.
• To convert to Imperial gallons per

minute, multiply by .833.

• To convert to litres per minute, multiply

by 3.78.

• To convert pounds per square inch

(PSI) to atmospheres, divide by 14.7.

• To convert pounds per square inch

(PSI) to kilograms per square
centimeter (kg/cm

2

) divide by 14.22.

• To convert feet to meters, divide by

3.28.

• To convert inches to millimeters, multiply

by 25.4.

A = 150°
B = 165°
C = 195°
D = 210°

All manuals and user guides at all-guides.com

Содержание 69-01

Страница 1: ...hydraulic normally open or 24 Volt electric systems Sprinkler Operating Mode Electric valve in head models have three modes of operation AUTO ON and OFF Mode is set using a selector tool inserted thr...

Страница 2: ...e 1 Triple Swing Joints Base Nozzle Set Nozzle Set Nozzle Set Pressure 90 91 92 Size 3 8 in Size 7 16 in Size 1 2 in PSI Rad GPM Rad GPM Rad GPM 40 50 60 78 ft 45 1 87 ft 53 7 70 82 ft 48 6 91 ft 57 2...

Страница 3: ...than 2 feet per second See Table 2 below 1 Use jockey pump only to fill system at velocity fill rate of less than 2 feet per second 2 Use quick coupler keys at all tees and greens with quick coupler v...

Страница 4: ...thin the system and maintains a constant pressure for optimum sprinkler operation The 690 series pilot valve is factory set to regulate at 80 or 100 PSI depending on sprinkler model Sprinkler operatio...

Страница 5: ...ine if closure is shut off valve or blockage and correct 6 Valve won t close a Leak in pilot valve assembly Replace pilot valve assembly Electric 69X 06 XX b Plugged supply screen on piston Clean or r...

Страница 6: ...provided on edge of stator 10 Thoroughly clean and inspect all parts Replace parts as required Note If changing nozzle to a different size appropriate stator must also be installed to ensure proper r...

Страница 7: ...tube and correctly seat the snap ring See Figure 6 NOTE It is possible to install the snap ring backwards upside down See inset in Figure 6 to insure that snap ring is installed in the correct manner...

Страница 8: ...om sprinkler body and cut control tubing just below tube retainer Unless pilot valve has been previously removed control tubing length will be sufficient for re connection 4 Remove tube retainer and r...

Страница 9: ...9973 Spring 100 lbs Blue 1 11 89 0029 Piston 1 12 89 0005 Diaphragm Assembly 1 SERVICE PARTS AND ASSEMBLIES 89 0009 Pilot Valve Assy 50 lbs Elec 89 0010 Pilot Valve Assy 65 lbs Elec 89 0011 Pilot Valv...

Страница 10: ...100 PSI 4 Full Circle 06 NPT Electric Valve In Head 92 6 Full Circle 2 Speed 08 NPT NC Valve In Head 60 120 8 Full Circle 2 Speed Pressure Regulation available on 180 180 Electric NC VIH models only A...

Страница 11: ...1 19 3 3355 Piston Assy Valve Drain 1 19 89 0937 Piston Assy Valve El Hyd NC 1 20 Body 690 See Service Items 1 21 9 6002 Adapter Tubing Threaded 1 4 1 22 89 8157 Cap Poly 1 4 1 23 900 40 Retainer Tube...

Страница 12: ...2001 The Toro Company Irrigation Division An ISO 9001 Certified Facility Form No 366 0041 Rev B All manuals and user guides at all guides com...

Отзывы: