background image

Set Rates Screen

To access the Set Rates screen, press button 2 on the Main
Menu screen (

Figure 6

) until you reach Set Rates and press

button 4 to select Set Rates (

Figure 7

).

This screen displays and allows you to set the Target Rate,
Rate 1, Rate 2, and the Boost-rate percentage.

To set Rate 1, Rate 2, or the Boost-rate percentage, refer to
the following:

1.

Press button 1 or 2 until you reach the desired rate or
boost-rate percentage (

Figure 7

).

2.

Press button 4 to select or edit the rate.

Figure 7

3.

In the screen for the selected rate, use buttons 3 and
4 to set the desired rate (

Figure 8

).

Note:

You can change the rate faster by pressing and

holding button 3 or 4.

Figure 8

Note:

From the home screen, press and hold buttons

1 and 2 simultaneously to select Rate 1 or press and
hold buttons 4 and 5 simultaneously to select Rate 2.

Note:

From the Home screen, press and hold buttons

1 and 5 simultaneously to apply boost rate.
Boost is active only as long as you hold buttons 1 and
5, then returns the set rate when you no longer press
and hold the buttons.

4.

Press button 5 to exit the Set Rates screen, to save the
rate setting, and return to the Main screen.

Settings Screen

To access the Settings screen, press button 2 on the Main
Menu screen (

Figure 6

until you reach Settings and press

button 4 to select Settings (

Figure 9

).

This screen allows you to view and change the settings for the
tank, display, boom width, and to reset default settings.

Figure 9

Tank Settings

1.

Press button 4 on the Settings screen to select Tank
settings (

Figure 9

).

2.

Press button 2 until you reach the item that you would
like to change (

Figure 10

).

3.

Use buttons 3 and 4 to set the desired value (

Figure 10

).

6

 

Содержание 41642

Страница 1: ...ard against personal contact with a chemical There may be more than 1 chemical used and information on each chemical should be assessed Refuse to operate or work on the sprayer if this information is...

Страница 2: ...er 4 Remove the clamps gaskets and manifold coupler Figure 1 Note Retain the clamps 5 Install the flow meter and 2 flow meter gaskets using the clamps that you just removed Figure 1 6 Remove the trans...

Страница 3: ...Switch 2 Plug 10 Install the switch into the hole Figure 4 11 Beneath the dashboard connect the wire harness to the switch then connect it to the machine wire harness Note The connector on the machine...

Страница 4: ...2 13 14 15 G035692 Figure 5 1 Master boom switch indicator on 5 Tank volume indicator US gallons 9 Selected application rate boost rate indicator on 13 Active application rate gpa 2 Right boom section...

Страница 5: ...at Figure 5 Selected Application Rate Boost Rate Indicator The selected application rate boost rate indicator displays when either the selected application rate and or the boost rate are active Figure...

Страница 6: ...usly to select Rate 1 or press and hold buttons 4 and 5 simultaneously to select Rate 2 Note From the Home screen press and hold buttons 1 and 5 simultaneously to apply boost rate Boost is active only...

Страница 7: ...3 Press button 1 or 2 until you reach the desired unit and then press button 4 to select this unit English mph gallons acre Turf mph gallons 100 ft SI metric kph liter hectare Change the InfoCenter d...

Страница 8: ...5 Enter PIN 3 Digit 3 3 From the PIN Settings screen press button 4 to select PIN Entry and to turn the PIN on or off Figure 16 Figure 16 Change the InfoCenter PIN as follows 1 Press button 2 on the...

Страница 9: ...Enter your new PIN using buttons 1 to 4 and press button 5 when you complete your new PIN Figure 19 Figure 19 1 Digit 1 4 Digit 4 2 Digit 2 5 Enter PIN 3 Digit 3 6 Confirm your new PIN using buttons 1...

Страница 10: ...ctions must be on when performing the catch test 8 Start at 2 75 bar 40 psi and use the application rate switch to adjust the spray pressure so a catch test yields the volume displayed for the selecte...

Страница 11: ...a Calibration Successful screen appears press button 5 to exit 12 If the calibration is not successful a Calibration Failed screen appears with the reasoning behind why the calibration failed press b...

Страница 12: ...ect About Figure 26 This screen displays the model number and serial number of your machine G034285 Figure 26 InfoCenter Spray Area Screens From the Home screen press and hold button 5 to open the men...

Страница 13: ...ub area 4 Volume sprayed in the active sub area US gallons 2 Area sprayed in the active sub area acres 5 Select the previous sub area hold the button to reset area and volume sprayed for the active su...

Страница 14: ...isories Condition Code Qualifier Display Text Start Prevented 2 Pump switch active To start turn pump off Start Prevented 3 Not in NEUTRAL To start return traction pedal to neutral Start Prevented 4 O...

Страница 15: ...Parameter Status 503 A value is outside the range of accepted values Parameter status invalid data defaults used Booms Turned Off 802 Speed dropped Booms turned off stopped or moving too slowly 15...

Страница 16: ......

Отзывы: