Corrected Meter Cal = (Meter Cal x Total Volume) /
Amount of Water

Corrected Meter Cal = (1660 x 103) /100

Corrected Meter Cal = 1710.

Note:

Repeat this procedure several times to confirm

that the corrected Meter Cal number is accurate.

Testing the Flowmeter Cable

1. Disconnect the console control cable from the

flowmeter cable.

2. Hold the cable so that the keyway is in the 12 o’

clock position (Figure 15).

G013306

1

2

3

4

Figure 15

1.

Keyway

3.

Signal (6 o’clock position)

2.

Ground (2 o’clock position)

4.

Power (10 o’clock position)

3. Enter a Meter Cal number. Refer to Entering the

Meter Cal Number on page 8.

4. Press the [Total Volume] key.

5. Turn the Pump, Foot, and Boom switches to the On

position.

6. Use a small jumper wire or a paper clip to create a

short between the 2 o’clock and 6 o’clock sockets.

Note:

Each time you make contact, the Total

Volume should increase by 1 or more counts.

7. If the Total Volume number does not increase,

replace the defective cable.

8. Perform the voltage checks: 2 o’clock to 6 o’clock

(+5 VDC); and 2 o’clock to 10 o’clock (+5 VDC).

9. If all the cables are good, replace the flow sensor.

Note:

After testing the flowmeter cables, enter the

correct Meter Cal number before spraying.

18

Содержание 41086

Страница 1: ...rol Spray System Multi Pro 5600 and 5700 D Turf Sprayer Model No 41086 Serial No 310000001 and Up To register your product or download an Operator s Manual or Parts Catalog at no charge go to www Toro...

Страница 2: ...320 1 Figure 1 1 Location of the model and serial numbers Model No Serial No This manual identifies potential hazards and has safety messages identified by the safety alert symbol Figure 2 which signa...

Страница 3: ...ar with these instructions to use the controls Never spray while people especially children or pets are nearby Chemicals can injure people animals plants soils or other property To avoid personal inju...

Страница 4: ...bolt 5 16 x 3 4 inch 4 Lock nut 5 16 inch 4 Computer console assembly 1 Hand Knob 2 Pivot bracket 2010 and newer only 1 Hose barb fitting 90 degree 1 Hose 49in length 1 Hose clamp 5 Screw flange head...

Страница 5: ...le with the large grommet 6 Plug the cables into their proper receptacles in the rear of the console computer 7 Secure the cables to the console computer by rotating the locking rings 8 Attach the con...

Страница 6: ...e plug in the wiring harness Closing the Boom Valves This system is designed to work with a diaphragm pump and must operate with the boom bypass valves closed Important Before operating the spray syst...

Страница 7: ...e to the right side of the tee fitting Retain the fork and one hose clamp 3 Locate the 90 degree fitting and long hose in loose parts Lightly lubricate the barb with a non petroleum based lubricant su...

Страница 8: ...ed shorter hose onto the outlet barb fitting of the flowmeter 13 Secure the shorter hose to the manifold and flowmeter respectively by sliding the hose clamps into positions over the barb and tighteni...

Страница 9: ...Enter key 4 Calibration keys Controls The ProContro System consists of a computer based control console a speed sensor and a turbine type flowmeter Become familiar with the controls Figure 12 before...

Страница 10: ...the spacing between them in inches cm of the center boom Enter 60 inches 152 cm as a default BOOM 3 CAL Length of boom 2 3 It calculates the length of the boom by multiplying the number of nozzles by...

Страница 11: ...ation The console computer automatically controls the spray application rate for varying vehicle speeds You set the target volume per unit area to spray and the console computer automatically maintain...

Страница 12: ...Cal by multiplying the number of spray tips by the tip spacing Note Boom 1 is the left boom from the operating position Boom 2 is the center boom and Boom 3 is the right boom 1 Press the Boom 1 Cal k...

Страница 13: ...number 1 Press the Valve Cal key 2 Press the Enter key 3 Enter the Valve Cal calibration number Note The initial valve calibration number for Valve Cal is 023 We recommend that you use this number for...

Страница 14: ...e Total Area key Note These parameters will alternately appear on the display Data Menu You use this key when you attach additional devices such as a data logger or a GPS Refer to the operating manual...

Страница 15: ...booms on This value is automatically proportional to the percentage of booms that are on For example if the entered low limit is 4 gal min and half of the total boom length is shut off the console au...

Страница 16: ...aying speed with the sprayer booms off 2 Press the Speed key to verify the speed readout 3 Turn the Spray pump control switch to Rate 1 4 Turn the Power switch to the On position 5 Turn the Foot switc...

Страница 17: ...r 50 kPa air jet to ensure that the turbine spins freely If it does not loosen the hex stud on the bottom of the turbine hub by 1 16 of a turn until the turbine spins freely Calibrating the Flowmeter...

Страница 18: ...10 o clock position 3 Enter a Meter Cal number Refer to Entering the Meter Cal Number on page 8 4 Press the Total Volume key 5 Turn the Pump Foot and Boom switches to the On position 6 Use a small ju...

Страница 19: ...ose 1 Secure the battery connections The console computer displays a flashing Cal whenever you turn the master switch to the On or Off position 2 The battery is not providing sufficient voltage 2 Chec...

Страница 20: ...Clean or replace the cable line 3 There is no voltage at the valve connector 3 Verify that there is voltage at the valve connector by placing the Master switch to the Man position with the booms in t...

Отзывы: