Enter key
This key allows you to enter data into the console
computer.
CE key
This key clears the data shown in the display; it also
enables you to toggle through the options found in
certain function keys.
The console computer allows the following parameters:
•
Area: US (acres); SI (hectares) or TU (1000 ft
2
)
•
Speed sensor type: SP1 (wheel drive, etc.), SP2
(radar), or SP3. This system uses the SP3 gear tooth
sensor. Refer to Initially Programming the Console
Computer on page 7.
The Console Keys
The keypad for the console computer is shown in Figure 13.
G013305
BOOM 1
CAL
1
BOOM 2
CAL
2
BOOM 3
CAL
3
SPEED
CAL
4
METER
CAL
5
VALVE
CAL
6
RATE 1
CAL
7
RATE 2
CAL
8
VOL
TANK
9
TIME
0
SELF
TEST
CE
TOTAL
AREA
TOTAL
VOLUME
FIELD
AREA
VOLUME
FIELD
DISTANCE
SPEED
MIN
VOL /
HOUR
AREA /
MENU
DATA
ENTER
Figure 13
Keypad Reference Table
Key
Description
Value
Function*
BOOM 1
CAL
Length of boom 1
1
It calculates the length of the boom by multiplying the
number of nozzles by the spacing between them in
inches (cm) of the left boom.
Enter
80
inches (
204
cm) as the default.
BOOM 2
CAL
Length of boom 2
2
It calculates the length of the boom by multiplying the
number of nozzles by the spacing between them in
inches (cm) of the center boom.
Enter
60
inches (
152
cm) as a default.
BOOM 3
CAL
Length of boom 2
3
It calculates the length of the boom by multiplying the
number of nozzles by the spacing between them in
inches (cm) of the right boom.
Enter
80
inches (
204
cm) as a default.
SPEED
CAL
Speed calibration number
4
It enables you to verify that the vehicle distance readout is accurate.
Enter
148
as a starting point for all Toro sprayers.
METER
CAL
Flowmeter calibration number
5
Enter the number found on the flowmeter label or the tag on the
flowmeter cable.
VALVE
CAL
Control valve response time
6
It sets the system response.
Enter
023
as a starting point. Note:
0
does not display but you
must enter it.
RATE 1
CAL
Target application rate 1
7
It is the first application rate.
RATE 2
CAL
Target application rate 2
8
It is the second application rate. If there is only one application
rate, use the Rate 1 value again.
VOL /
TANK
Volume of material remaining in the
tank
9
It displays the volume of material in the sprayer tank. Reset the
volume when you refill the tank.
TIME
24-hour clock
0
It is a 24 hour clock or an elapsed timer. You reset it when you
turn off the console computer.
SELF
TEST
Simulation of vehicle speed
Backspace It simulates the vehicle speed to allow the operator to check and
calibrate the system operation.
10