Troubleshooting
Alert and Error Messages
Message
Icon
Description
Resolution
Voltage Error
The ignition key is in the
RUN
position and the smart
controller/electronic depth
control measures that the
electrical system is less than
12.3V or greater than 16V.
The voltage error icon displays,
and the LED status light flashes
a red.
Check the battery, charging
system, and wiring.
Valve Solenoid Overcurrent
Error
An over-current event occurs at
the solenoid valve.
The valve solenoid over-current
error displays with the number
2 and the LED status light
flashes a red.
Check the valve solenoid and
inspect it for damage and wear.
Valve Solenoid Open Error
1 of the 2 valve solenoids
or both valve solenoids are
disconnected.
The valve solenoid open error
displays with the number 6 and
the LED status light flashes a
red.
Connect the valve solenoid(s).
Valve Solenoid Connection
Error
The valve solenoids are
connected wrong (the
connector for the relief valve is
connected to the other valve
solenoid).
The valve solenoid connection
error alert displays, and the
tines will not operate until the
fault is corrected.
Swap the valve solenoid
connectors.
Troubleshooting Table
Problem
Possible Cause
Corrective Action
1. The parking brake is not engaged.
1. Engage the parking brake.
2. The battery does not have a full
charge.
2. Charge the battery.
3. The electrical connections are
corroded, loose or faulty.
3. Check the electrical connections for
good contact. Clean the connector
terminals thoroughly with electrical
contact cleaner, apply dielectric
grease, and reconnect.
4. A fuse is blown.
4. Replace the blown fuse.
The starter does not crank.
5. A relay or switch is not functioning
properly.
5. Contact an Authorized Service Dealer.