Figure 18
Wiring harness with cable ties
7.
Route the connectors marked Setup Valve up to the
9-section valve block to the top solenoid marked Setup
Valve (
8.
Disconnect the connector from the top solenoid valve
and plug it into the mating connector on the new
harness.
9.
Plug the other connector into the valve you previously
disconnected.
10.
Locate the round connector on the existing harness
that was previously connected to the proximity sensor
(
).
11.
Unscrew the connector, remove the cable ties securing
this wire, and attach the existing connector to the
connector on the new harness (
12.
Route the remainder of the new harness along the
existing harness under the thrust frame (
).
13.
Route the wires with the Rotary Sensor connector
along the thrust frame with the existing harness toward
the rear of the machine and continue to route the
harness along the hydraulic lines as shown in
Figure 19
Wiring harness with cable ties
14.
Connect the connectors to the proximity sensor and
the rotary sensor (
Note:
Secure the wiring harness to the machine as
shown in
Figure 20
15.
Install the latest version of software into the machine
and complete the tests described in that software
update.
4
Removing the Rotary Pump
Supply and Drain Orifices
Parts needed for this procedure:
1
Gasket
Removing the Rotary Pump Supply and
Drain Orifices
Important:
Allow the engine to cool.
1.
Place a oil pan under the machine to catch oil from
the rotary pump.
2.
Remove and plug the case drain line from the rotary
pump and cap off the case drain fitting to minimize
hydraulic fluid loss.
9