![Toro 04730 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/toro/04730/04730_installation-instructions-manual_1133964006.webp)
g016178
Figure 10
1.
Plug (replaces the
breather)
3.
Sight window
2.
Fill with hydraulic fluid to
top off the main hydraulic
tank here.
2.
Install a plug in place of the breather (
).
3.
Trim the dipstick to the marked trim line shown
in
. Ensure that the trimmed end is
smooth; deburr the end as needed.
g236710
Figure 11
1.
9.5 cm (3-3/4 inches)
3.
Appropriate hydraulic fluid
level
2.
Trim the dipstick here.
4.
Fill the leak detector tank according to the
characteristics of your leak detector tank, as
follows:
•
If your leak detector tank
has
a sight window:
Fill the leak detector tank with hydraulic fluid
until the fluid level is at the middle of the
sight window.
•
If your leak detector tank
does not have
a
sight window:
Fill the leak detector tank with hydraulic fluid
until the fluid level is at the middle of the fill
marks on the dipstick; refer to
.
5.
Install the dipstick on the leak detector tank
(
).
g236731
Figure 12
1.
Dipstick
2.
Leak detector tank
6.
Install the console arm cover using the hex-head
screws that you previously removed.
7.
Connect the battery; refer to your machine
Operator’s Manual
.