2
Installing the Manifold
Parts needed for this procedure:
1
Manifold
7
Hydraulic fitting, straight
2
Diagnostic fitting
2
Dust cap
3
Bolt (3/8 x 1-3/4 inches)
3
Lockwasher (3/8 inch)
3
Spacer
Procedure
1.
Install 4 straight hydraulic fittings into the rear of the
manifold (Figure 4).
Figure 4
1.
Manifold
4.
Dust cap (2)
2.
Straight fitting, rear install
(4)
5.
Straight fitting, underside
install (3)
3.
Diagnostic fitting (2)
2.
Install 2 diagnostic fittings into either side of the
manifold along with dust caps (Figure 4).
3.
Install 3 straight hydraulic fittings into the bottom of
the manifold (Figure 4).
4.
Mount the manifold assembly to the underside of the
manifold bracket with 3 bolts (3/8 x 1-3/4 inches),
lock washers (3/8 inch) and spacers. Position the
spacers between the manifold bracket and the top of
the manifold. The manifold is to be positioned so the
fittings point to the rear, and down (Figure 5).
Note:
Make sure the O-rings are lubricated and in
position on all of the fittings before installation.
Figure 5
1.
Manifold assembly
4.
Bolt (3/8 x 1-3/4 inches)
2.
Machine frame
5.
Lock washers (3/8 inch)
3.
Spacer
3
Installing the Wheel Motor
Hoses
Parts needed for this procedure:
4
Hydraulic hose
Procedure
1.
Loosely thread the 45 degree fitting end of each
hydraulic hose onto the straight fittings at the rear of
the manifold (Figure 6).
Figure 6
1.
LH fitting, at 10 degrees
2.
RH fitting, at 10 degrees
2.
Route the 2 left hoses to the left wheel motor. Connect
the upper manifold hose to the upper wheel motor
4
Содержание 03655
Страница 11: ...Schematics Hydraulic Schematic Rev A 11...