Toro 02891 Скачать руководство пользователя страница 3

Safety

WARNING

If you do not follow certain safety procedures,
someone could be seriously injured.

Before working on the machine, ensure the
following:

The engine is switched off.

The parking brake is applied.

There is no pressure in the hydraulic system.

The cutting units are fully down on the ground.

WARNING

Performing maintenance without eye protection
could result in serious injury.

When carrying out maintenance operations always
wear eye protection.

WARNING

Working on the electrical system in an unsafe
manner could result in serious injury.

Before working on the electrical system of the
machine, always disconnect the battery terminals
(negative terminal first) and ensure that no contact
is made between the terminals and the metal
components of the machine.

General Safety

If a fault arises in the air-conditioning system then it must
be inspected and repaired by qualified personnel.

Never allow refrigerant to be discharged into the
atmosphere.

Never attempt to warm any part of the air-conditioning
system with an open flame.

Never allow refrigerant to come into contact with the
skin. Refer to the refrigerant data sheet for guidance.

Wear suitable personal protective equipment when
handling refrigerant.

Never carry out soldering or welding on or near any
parts of the air-conditioning system as heat can cause
expansion and rupture of the components.

Always allow the air-conditioning system to cool down
before working on any part of it.

To ensure optimum performance and continued safety
certification of the machine, use only genuine Toro

replacement parts and accessories. Replacement parts and
accessories made by other manufacturers could be dangerous,
and such use could void the product warranty.

Safety and Instructional
Decals

Safety decals and instructions are easily
visible to the operator and are located near
any area of potential danger. Replace any
decal that is damaged or lost.

978004

1.

Cooling/air-conditioning
system

3.

High-pressure
fluid—hazard of injection
into the body

2.

Read the

Operator’s

Manual

.

4.

Poisonous fumes or toxic
gases—asphyxiation
hazard

3

 

Содержание 02891

Страница 1: ...Form No 3395 604 Rev A Air Conditioning Kit Mauser KS 534 Full Safety Cab Model No 02891 Register at www Toro com Original Instructions EN 3395 604 A...

Страница 2: ...numbers of your product ready Write the numbers in the space provided Model No Serial No This manual identifies potential hazards and has safety messages identified by the safety alert symbol Figure...

Страница 3: ...mosphere Never attempt to warm any part of the air conditioning system with an open flame Never allow refrigerant to come into contact with the skin Refer to the refrigerant data sheet for guidance We...

Страница 4: ...4 1 2 3 Figure 2 Evaporator heater and fans mounted in front of the cab roof 1 Air conditioner evaporator heater and double radial blower 3 Expansion valve 2 Heater valve g018399 Figure 3 Compressor...

Страница 5: ...n rear of the cab roof 1 Condenser 3 Pressure switch 2 Dryer filter Controls The controls are mounted on the right side in the roof lining G025784 1 2 0 3 Figure 5 1 3 position switch for radial blowe...

Страница 6: ...l performance of your Toro equipment count on Toro genuine parts When it comes to reliability Toro delivers replacement parts designed to the exact engineering specification of our equipment For peace...

Страница 7: ...m for many months of the cutting season Follow the regular prescribed maintenance to prolong the life of the system and ensure efficient operation Failure to carry out the prescribed and documented ma...

Страница 8: ...rigerant quantity is too low check the sight glass The compressor speed is too low check the drive belt for slip tension There is a fault with the compressor Pressure on low pressure manometer too hig...

Страница 9: ...he cab Figure 8 Check the water drain for blockages and clean as necessary If the tube is blocked use a flexible unblocking tool pipe cleaner or disconnect the tube and blow it out with compressed air...

Страница 10: ...n the bolts 4 Check the deflection of the belt again to ensure that the tension is correct Locating the Fuses The fuse box is located in the cab roof liner in front of the driver g018402 1 2 3 4 Figur...

Страница 11: ...Schematics g01840 1 2 1 3 4 9 8 5 6 10 7 11...

Страница 12: ...pansion valve 3 Evaporator combined with heat exchanger for heating 4 Condenser water 5 Compressor 6 Condenser 7 Axial fans 8 Dryer filter 9 Sight glass 10 Drain Functional schematic of the air condit...

Страница 13: ...5A 7 in 5k 1 1 2 2 L M B H C 3 3 6 5 4 30 87 85 86 30 87 84 85 30 A 15 A 5A 4 in 5k 6 in 5k 3 in 5k 23 A 30 87 85 86 30 15 1 2 4 6 7 9 5 10 8 3 10 g019147 13...

Страница 14: ...netic clutch 3 Twin axial fans 4 Temperature sensor 5 Electronic regulator 6 Radial blower fan 7 Blower speed switch 8 Pressure switch 9 Main fuse in engine compartment 10 Relay Electrical schematic o...

Страница 15: ...ompiled as required per Part B of Annex VII of 2006 42 EC We will undertake to transmit in response to requests by national authorities relevant information on this partly completed machinery The meth...

Страница 16: ......