Checking the Refrigerant
Pressure

When using the air-conditioning system the operating
pressure is different on the suction side and the pressure side
of the compressor.

This pressure difference is influenced by the speed of the
compressor, the inside temperature of the vehicle, the outside
air temperature and the relative air humidity.

Pressures that differ from those in the table below indicate a
possible fault in the system.

To check the pressures, set the compressor speed to 2000
rpm with an air temperature between 20 and 40 degrees C (68
and 104 degrees F). Operate the blower at position 3 (fastest
speed setting).

System Refrigerant Pressures

Outside Temperature

Low-Pressure Side

High-Pressure Side

20° C (68° F)

1.7 to 2.1 bar (24.7 to 30.5 psi)

10 to 14 bar (145 to 203 psi)

25° C (77° F)

1.8 to 2.2 bar (26.1 to 31.9 psi)

12 to 16 bar (174 to 232 psi)

30° C (86° F)

1.9 to 2.3 bar (27.6 to 33.4 psi)

14 to 18 bar (203 to 261 psi)

Troubleshooting the Pressure
Readings

During the compression test, deviations from the values in
the table may be measured. Locating the cause can determine
whether a part requires repair or replacement.

The following is a short list of some pressure deviation that
may be measured and some possible causes.

Pressure on high-pressure manometer too high

The air volume in the condenser is too small.

Refrigerant quantity is too high

The dryer/filter is blocked.

Pressure on high-pressure manometer is too low

The refrigerant quantity is too low (check the sight
glass).

The compressor speed is too low (check the drive
belt for slip/tension).

There is a fault with the compressor.

Pressure on low-pressure manometer too high

The expansion valve is incorrect.

The compressor speed is too low (check the drive
belt for slip/tension).

There is a fault with the compressor.

Pressure on low-pressure manometer too low

There is restriction in the suction or pressure hoses.

The expansion valve is incorrect.

The refrigerant quantity is too low (examine the
sediment bowl).

The air volume in the evaporator is too small.

Have a qualified person examine and repair all deviations
in pressure from the values in the table.

Important:

Do not allow refrigerant to discharge into

the atmosphere. Before opening or disconnecting parts

from the refrigerant circuit, empty the refrigerant into a
specified recycling bottle, and dispose of it correctly.

Always use genuine Toro spare parts when repairing or
servicing the air-conditioning system.

Checking the Refrigerant Level

Service Interval:

Every 50 hours

Check the refrigerant to assure it is at the correct level for
operation. As the level of the refrigerant lowers, more
air bubbles can be seen passing through the sight glass.
Low levels of refrigerant can reduce the efficiency of the
air-conditioning unit. Extremely low levels can cause the
low-pressure switch to shut down the system.

1.

Using the sight gauge in the collecting tank, check on
refrigerant level (

Figure 6

).

g019080

1

Figure 6

1.

Refrigerant-level sight gauge

2.

After filling, run the system for 5 minutes to allow all
air bubbles to be purged from the system.

8

 

Содержание 02891

Страница 1: ...Form No 3395 604 Rev A Air Conditioning Kit Mauser KS 534 Full Safety Cab Model No 02891 Register at www Toro com Original Instructions EN 3395 604 A...

Страница 2: ...numbers of your product ready Write the numbers in the space provided Model No Serial No This manual identifies potential hazards and has safety messages identified by the safety alert symbol Figure...

Страница 3: ...mosphere Never attempt to warm any part of the air conditioning system with an open flame Never allow refrigerant to come into contact with the skin Refer to the refrigerant data sheet for guidance We...

Страница 4: ...4 1 2 3 Figure 2 Evaporator heater and fans mounted in front of the cab roof 1 Air conditioner evaporator heater and double radial blower 3 Expansion valve 2 Heater valve g018399 Figure 3 Compressor...

Страница 5: ...n rear of the cab roof 1 Condenser 3 Pressure switch 2 Dryer filter Controls The controls are mounted on the right side in the roof lining G025784 1 2 0 3 Figure 5 1 3 position switch for radial blowe...

Страница 6: ...l performance of your Toro equipment count on Toro genuine parts When it comes to reliability Toro delivers replacement parts designed to the exact engineering specification of our equipment For peace...

Страница 7: ...m for many months of the cutting season Follow the regular prescribed maintenance to prolong the life of the system and ensure efficient operation Failure to carry out the prescribed and documented ma...

Страница 8: ...rigerant quantity is too low check the sight glass The compressor speed is too low check the drive belt for slip tension There is a fault with the compressor Pressure on low pressure manometer too hig...

Страница 9: ...he cab Figure 8 Check the water drain for blockages and clean as necessary If the tube is blocked use a flexible unblocking tool pipe cleaner or disconnect the tube and blow it out with compressed air...

Страница 10: ...n the bolts 4 Check the deflection of the belt again to ensure that the tension is correct Locating the Fuses The fuse box is located in the cab roof liner in front of the driver g018402 1 2 3 4 Figur...

Страница 11: ...Schematics g01840 1 2 1 3 4 9 8 5 6 10 7 11...

Страница 12: ...pansion valve 3 Evaporator combined with heat exchanger for heating 4 Condenser water 5 Compressor 6 Condenser 7 Axial fans 8 Dryer filter 9 Sight glass 10 Drain Functional schematic of the air condit...

Страница 13: ...5A 7 in 5k 1 1 2 2 L M B H C 3 3 6 5 4 30 87 85 86 30 87 84 85 30 A 15 A 5A 4 in 5k 6 in 5k 3 in 5k 23 A 30 87 85 86 30 15 1 2 4 6 7 9 5 10 8 3 10 g019147 13...

Страница 14: ...netic clutch 3 Twin axial fans 4 Temperature sensor 5 Electronic regulator 6 Radial blower fan 7 Blower speed switch 8 Pressure switch 9 Main fuse in engine compartment 10 Relay Electrical schematic o...

Страница 15: ...ompiled as required per Part B of Annex VII of 2006 42 EC We will undertake to transmit in response to requests by national authorities relevant information on this partly completed machinery The meth...

Страница 16: ......

Отзывы: