298061_en - 07/12
1. Installation conditions - Instruction Manual - EvoDECO 10/10 & 10/8
1-10
1.5.
Energy supply connection specifications
1.5.1.
Electrical connection
1.5.2.
Pneumatic connection
Name
Unit
Value
Electric power
kVA
10
Protection fuse against intensity overloads
A
20
Power supply voltage
VAC
400
Power supply tolerance
%
+/- 5
Power supply frequency
Hz
50
Mandatory!
The machine must be supplied with dry air and without oil.
If the air of your network contains oil or condensate it is necessary to install an air dryer at the
circuit inlet to avoid malfunctioning or breakdowns of the machine.
Quality according to ISO 8573-1
Name
Unit
Value
Operating pressure
bar
6
Average consumption of 6 bar system (max)
m
3
/h
20
Flow rate
l/min
100
Quality class, shop standard
-
4
Maximum particle size
µm
15
Mass concentration
mg/m
3
8
Maximum pressurised dew point
°C
+ 3
Maximum concentration in oil
mg/m
3
5
Fast connection
-
G 1/4"
Содержание EvoDECO 10/10