M531 M14 M1
Start spraying valve 4. 15 bar pump with 3 outlets.
M532 M1 M0
Stop High Pressure Pump.
M532 M1 M1
Start High Pressure Pump.
M532 M11 M0
HP pump.
(120-340bars solenoid valve YV70 closing)
M532 M11 M1
HP pump.
(120-340bars solenoid valve YV70 opening)
M532 M12 M0
HP pump.
(120-340bars solenoid valve YV71 closing)
M532 M12 M1
HP pump.
(120-340bars solenoid valve YV71 opening)
M532 M13 M0
HP pump.
(120-340bars solenoid valve YV72 closing)
M532 M13 M1
HP pump.
(120-340bars solenoid valve YV72 opening)
M532 M14 M0
HP pump.
(120-340bars solenoid valve YV73 closing)
M532 M14 M1
HP pump.
(120-340bars solenoid valve YV73 opening)
M702 M2 My
+ M702 M4 M1
Activation of the torque limit.
(Z41) (+for all axes)
M702 M3 My
+ M702 M5 M1
Activation of servo-lag control.
(Z41) (+for all axes)
M702 M4 M0
Cancellation of the torque limit.
(Z41) (+for all axes)
M702 M5 M0
Cancellation of servo-lag control.
(Z41) (+for all axes)
M74x M1 M0
Deactivated auxiliary spindle rotation.
(X=number of auxiliary spindles)
M74x M1 M1
Activated auxiliary spindle rotation.
(X=number of auxiliary spindle)
M74x M2
Auxiliary speed set point spindle.
(initialised with M200)(X=number of auxiliary spindle)
M74x M3
Auxiliary spindle M3.
(X=number of auxiliary spindle)
M74x M4
Auxiliary spindle M4.
(X=number of auxiliary spindle)
M74x M5
Auxiliary spindle M5.
(X=number of auxiliary spindle)
M751 M1 M0
Stop thread whirling device 1.
M751 M1 M1
Start thread whirling device 1.
M751 M2 M0
Stop thread whirling device 2.
M751 M2 M1
Start thread whirling device 2.
M841 M1 M0
Counter spindle cleaning -> Air Deactivation.
M841 M1 M1
Counter spindle cleaning -> Air Activation.
M841 M3 M0
Counter spindle cleaning -> Oil Deactivation.
M841 M3 M1
Counter spindle cleaning -> Oil Activation.
Содержание DECO 20/10 PTO
Страница 4: ...Page 4 of 26 2 MACHINE SPECIFICATIONS 2 1 SYNOPTIC TABLE ...
Страница 8: ...Page 8 of 26 2 6 KINEMATICS ...
Страница 17: ...Page 17 of 26 3 4 4 Tool grid ...
Страница 26: ...Page 26 of 26 ...