QUICK REFERENCE − DECO 13A
en 300417 − 04/08
12
M/S
Grp.
Function
Code
G550
Cancelling of polygon mode S5 spindle activa-
ted over G551. Polygon mode to be cancelles
over a M505 or M503 S function.
G551
Activation of S5 spindle (identified by hundreds)
in polygon mode
R2 Q−0 does not reverse the sense of rotation
R2 Q−1 reverses the sens of rotation
G900
Initialize spindles with settings specified for part
G901
Initialize sequences
*
Functions active by default for new operation
Grp.
Function Group Nb.
M
Modal:
Function remains active until replaced by another function of
same group
S
Sequential:
Function remains active in programmed segment only.
Содержание DECO 13a
Страница 1: ...QUICK REFERENCE DECO 13a en 300417 Printed in Switzerland Copyright 1999 2008 ...
Страница 28: ...QUICK REFERENCE DECO 13A en 300417 04 08 28 1 13 KINEMATICS ...
Страница 45: ...QUICK REFERENCE DECO 13A en 300417 04 08 45 4 DRIVE ...
Страница 46: ...QUICK REFERENCE DECO 13A en 300417 04 08 46 4 1 307005 S2 DRIVE X2 Y2 307005f3 ...
Страница 48: ...QUICK REFERENCE DECO 13A en 300417 04 08 48 4 3 307010 S6 DRIVE X1 Y1 307010f3 ...
Страница 52: ...QUICK REFERENCE DECO 13A en 300417 04 08 52 5 7 REFILLING CHUCKING HYDRAULICS OK KO Y360 1 2 3 4a 4b 5 6 0 ...