18
TORNADO
USE AND MAINTENANCE MANUAL
428000393
237
EN
UPRIGHT DISPLAY CABINETS
9. MAINTENANCE
The Staff in charge of the appliance must control and respect the expiry dates for maintenance,
given in the table below, calling the authorised Technical After-sales assistance when indicated.
OPERATION
FREQUENCY
ORDINARY
EXTRAORDINARY
AUTHORISED
PERSONNEL
Depending on the Use and Necessity
Monthly
six
-month
Annual
CLEANING THE EXTERNAL SURFACES
X
X
USER
CLEANING THE ACCESSIBLE INTERNAL PARTS
(without the use of tools)
X
X
CONTROL POWER SUPPLY CABLE,
PLUGS AND / OR ELECTRICAL SOCKETS
X
X
INTEGRITY CONTROL SEAL
X
X
FILTER CLEANING CONDENSING UNIT
(whenever present)
X
X
CLEANING THE DEFROSTING WATER COLLECTION TRAY
X
X
TECHNICAL
ASSISTANCE
SERVICE
CONDENSER CLEANING
X
X
X
CHECK COMPRESSORE OIL LEVEL
(whenever present)
X
X
AIR TANK DRAINING
(whenever present)
X
X
CONTROL PNEUMATIC CONNECTIONS
(whenever present)
X
X
INTEGRITY CONTROL PIPE COOLING SYSTEM
X
X
INSPECTION OF CABLES
INTERNAL CONNECTIONS AND POWER
X
X
CLEANING CONDENSATE DRYING SPONGES
(whenever present)
X
X
LAMP / LED REPLACEMENT
(whenever present)
X
CONTROL PANEL REPLACING
(electronic control unit - thermostat - etc)
X
REPLACEMENT POWER SUPPLY CABLE, PLUGS AND / OR ELECTRICAL SOCKETS
X
Attention
After all maintenance it is mandatory to perform all electric safety tests in agreement with the IEC EN 50106
Standard.