Tornado Pro Spotter Скачать руководство пользователя страница 7

4

Your new Tornado unit is a high quality, precision-made product. All parts used in the manufacturing 
of this unit have passed rigid quality control standards prior to assembly. Please safeguard the original 
receipt / invoice. If you experience any problems with your unit during the warranty period, the original 
receipt / invoice will act as proof of purchase. Contact Tornado for any warranty inquiries.

IMPORTANT SAFETY INSTRUCTIONS
READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS UNIT

Read and understand this owner’s manual and all labels on the unit before operating. Safety is a 
combination of common sense,staying alert and knowing how your unit works. Use this unit only as 
described in this manual. Use only manufacturer’s recommended attachments. To reduce the risk of 
personal injury or damage to your unit use only Tornado recommended accessories.

W

ARNING 

To avoid fire, DO NOT use with a flammable or combustible liquid or floor cleaner.

WARNING 

To avoid electric shock, DO NOT expose to rain. Store Indoors.

To reduce risk of fire, electric shock, or injury:
•  Do not use outdoors or on wet surfaces. 
•  Do not leave unit unattended when plugged in. Turn off the switch and unplug the electrical cord 

when not in use and before servicing. 

•  Do not allow to be used as a toy. Close attention is necessary when used near children.
•  Use only as described in this manual. Use only manufacturer’s recommended attachments. 
•  Do not use with damaged cord or plug. If unit is not working as it should, has been dropped, 

damaged, left outdoors, or dropped into water, return it to a service center before using.

•  Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull a cord around sharp 

edges or corners.  Do not run the unit over cord. Keep cord away from heated surfaces. 

•  Do not use extension cords or outlets with inadequate current carrying capacity. 
•  Turn off all controls before unplugging. 
•  Do not handle plug or unit with wet hands. 
•  Do not put any objects into openings.  Do not use with any opening blocked, keep free of dust, lint, 

hair, and anything that may reduce airflow. 

•  Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts. 
•  Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
•  Use extra care when cleaning on stairs. Do not use to pick up flammable or combustible   liquids such 

as gasoline, or use in areas where they may be present. 

•  Store your unit indoors in a cool, dry area. 
•  Do not unplug by pulling on cord. To unplug, grasp the plug, NOT THE CORD.
•  Follow these guidelines to ensure operator safety and to maintain equipment in running order.
•  Make sure the machine is plugged into an electrical outlet with the same voltage rating as shown on 

the nameplate of the machine.

•  Do not attempt to plug a 115 volt machine into a 230 volt outlet or a 230 volt machine into a 115 outlet.
•  Replace a damaged cord immediately.
•  If an extension cord is necessary, use a three conductor grounding cord-12 gauge wire or heavier to 

prevent motor burnout and over-heating of wires

•  Do not expose the machine to freezing temperatures.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

IMPORTANT SAFETY INSTRUCTIONS

Содержание Pro Spotter

Страница 1: ...Pro Spotter Operations and Maintenance Manual For Commercial Use Only Model No TE011 G03 U...

Страница 2: ...NOTES...

Страница 3: ...duction 1 Warranty 2 GroundingInstructions 3 Important Safety Instructions 4 TechnicalSpecifications 6 Operating Instructions Key Features 7 Operation 7 Transport and Storage 12 Maintenance 13 Trouble...

Страница 4: ...or damage Unpack all internal parts ensure no hidden damage is found Each unit is tested and thoroughly inspected prior to shipping If damage is discovered immediately notify the transportation compan...

Страница 5: ...hazardous situation that could result in death or serious injury if not avoided Use only as described in this manual There are no owner serviceable parts inside this machine Removal of screws and acc...

Страница 6: ...ith all local codes and ordinances Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service person if you are in do...

Страница 7: ...ld has been dropped damaged left outdoors or dropped into water return it to a service center before using Do not pull or carry by cord use cord as a handle close a door on cord or pull a cord around...

Страница 8: ...bleach dissolves in water two substances form which play a role in both disinfection and oxidation Manufacturer s recommendations must be followed for the chemical being used to ensure the proper bala...

Страница 9: ...ray Mode 1A Extraction Mode 8 9A Solution Tank 3 5 Gal 13 2 l Recovery Tank 2 5 Gal 9 5 l Dimensions 23 x 11 x 23 58 5cm x 28cm x 58 5 cm Weight 41 lbs 18 5 kg Waterlift 89 226 cm CFM CMM 104 3 Soluti...

Страница 10: ...ve warning instructions will void the warranty When using as an extractor Do not use the machine for totally dry vacuuming This machine is not fitted with a fine dust filter Do not use citrus based cl...

Страница 11: ...ine Turn the 3 way switch to SPRAY setting Allow approximately 30 seconds for the pump to prime Use the wand with spray tip to spray the solution The atomizing nozzle that is pre installed on the wand...

Страница 12: ...fan nozzle spray tip is for application in areas like warehouses shipping carts etc where there is not a worry that the items being sprayed could get oversaturated This allows for a quicker applicati...

Страница 13: ...e hose end Use the wand to spray and recover the solution The float shut off will disable the suction of the unit when the recovery tank is full The operator will notice a distinctive change in the so...

Страница 14: ...11 Solution Hose Connection 3 Way Switch OPERATION...

Страница 15: ...ine ensure that all components tanks and remov able parts are securely fastened and that the power cord and plug are not trail ing 7 DO NOT lift or transport the machine while it contains liquid as th...

Страница 16: ...ment part 3 SOLUTION FEED FILTER The filter prevents clogging of the pump and spray nozzle and should be periodically cleaned 4 NOZZLE MAINTENANCE If the spray jets become clogged remove and soak the...

Страница 17: ...n the hose in the solution tank Clean the spray jet in the hand tool Low Suction Recovery tank is full Clogged Hand Tool or hose Excessive foam Empty recovery tank Clean Hand Tool and hose Add defoame...

Страница 18: ...15 PARTS DIAGRAM...

Страница 19: ...bly 1 15 PX30 KIT Filter and Hose Sub Assembly 1 16 PX46 Lock Nut 1 17 PX209 Foam Filter 1 18 X9079 Gasket 1 19 X2045 Fill Label 1 20 X1920BLK Solution Tank 1 21 PC66 Fitting 1 4 HB x 1 8 MPT 1 22 718...

Страница 20: ...Clamp 2 49 FJ5082 Pump w o Mounts No Fittings 1 50 PX204 Pimp Mount 2 51 PX214 Nylon Elbow Fitting 90 1 4 HB x 1 8 MPT 1 52 7DL003 Hose Clamp 4 53 X8271 Nyloc Nut 5 54 X9064 Gasket 1 55 72697A Hose 8...

Страница 21: ...18 1 3 2 X9082 KIT No Part No Qty Description 1 X9082 1 PVC Pipe 1 1 2 x 6 1 2 2 X9076 1 Bulkhead Fitting 1 1 2 MPT x 1 1 2 Female Slip 3 PX14A 1 Gasket PARTS LISTING...

Страница 22: ...Filter 2 PX213 1 Nylon Fitting 1 4 MPT x 1 4 Hose Barb 3 7DL003 2 Hose Clamp 4 71817A 1 Braided Hose 1 4 250 P S I 5 7AT006 1 Brass Fitting 90 1 4 Barb x 1 4 MPT 6 72115A 1 Washer 7 7AJ004 1 Brass Anc...

Страница 23: ...20 NOTES...

Страница 24: ...21 T OM TE011 G03 U 02 2022...

Отзывы: