5
Filling the Pro Spotter
• Unplug the unit.
• Disconnect the solution and recovery tanks.
• Remove the upper recovery tank.
• Add water and/or chemicals to the lower solution tank. Fill only to the fill line indicated on the
label on the inside of the solution tank. The tank will hold up to 3.5 gallons.
Operating the Pro Spotter
• Attach the solution hose to the quick disconnect in the pocket at the front of the machine.
• Attach the vacuum hose to the vacuum inlet (handle) above the recovery tank lid.
• Turn the 3-way switch to use either the pump and vacuum or the vacuum alone. (Allow
approximately 30 seconds for the pump to prime).
• Use the hand tool to spray and recover the solution.
• The float shut-off will disable the suction of the unit when the recovery tank is full. The
operator will notice a distinctive change in the sound of the vacuum motor when the shut-off
is activated. Empty the recovery tank, and then fill the solution tank, to resume cleaning.
Emptying the Recovery Tank
• Unplug the unit.
• Disconnect the solution line and vacuum hose.
• Unlatch the recovery tank from the base of the unit and remove.
• Remove the drain plug.
• Drain the tank over a suitable outlet for wastewater.
• Rinse the tanks after each use.
• Store the unit with the lid off of the recovery and allow it to air dry.
OPERATING INSTRUCTIONS
Vacuum Hose Attachment
Latch Assembly
Recovery Tank Drain
*Always follow manufacturer instructions*