13
Water dripping from bottom of machine exhaust.
Check machine for excess foaming. Add CFR Defoam to tool hose and
tank. Open machine top cover and let vacuum run for 10 minutes to dry
out vacuum motor, then close lid and resume cleaning.
Vacuum hose or tool leaks.
Leave vacuum running for 1 minute when finished cleaning to clear hose.
Check for holes/breaks in vacuum hose.
Make sure the inline strainer is properly tightened and fluid hose
connectors are fully seated.
Carpet too wet.
NOTE: CFR floor tool is used in forward direction only.
Check carpet tool position – head must be completely “seated” on carpet
to provide good drying times.
Check tool and hose for any obstructions.
Check lid cover sealing properly – is filter case properly seated in tank? Is
lid gasket in good shape with no cuts, cracks, or worn/compressed areas?
Check for cracks in lid cover.
Check drain hose and fittings for cracks and tears.
Check tool hose for holes, cracks, or cuts.
Check hose cuffs – must seat firmly on tank fitting and tool.
Check water dripping from bottom of machine exhaust. If present, check
machine for excess foaming.
Check carpet installation. Some carpets are installed on uneven surfaces
with ridges and umps. It is difficult to get good drying times with this type
of installation.
Streaks on carpet.
Check tool and hose for obstructions.
Check and clean inline strainer filter.
Check and clean main filter.
Check and clean stainless back flush filter screen inside tank.
Check nozzles for full spray. Clean if clogged or replace if worn.
Check pump pressure drop while cleaning. Should not drop more than
100 p.s.i. Make sure air is out of system by re-priming pump. If there is still
a problem, remove and clean back flush filter screen.
Make sure strokes overlap a minimum of 3 inches.
Check CFR chemical usage instructions for proper application.
Multiple cleanings may be needed to clean deeply imbedded dirt that is
pulled to the surface. Offset cleaning passes by 6 inches.
Excessive pressure drop when cleaning.
Adjust static pressure to 500/750 p.s.i. when not cleaning.
(exceeds 100 p.s.i.)
Check and clean main filter and inner stainless back flush filter.
Check and replace worn spray nozzles and loose or leaking fittings on
hose.
Purge excess air from pumping system using hose with no nozzle or
priming hose.