Tornado 97130 Скачать руководство пользователя страница 2

Long Term Buyer Protection Limited Warranty

10 Years*

Plastic water tanks and Rotationally-molded bodies

2 Years*

Parts on all Tornado cleaning equipment

1 Year*

Labor on all Tornado cleaning equipment

1 Year*

Warranty on batteries, one year prorated

All battery warranties are handled directly by the battery manufacturer, on a one year prorated basis

Tornado Industries, LLC. (Tornado) warrants to the end/user customer that the Tornado product(s) will 

be free from defects in material and workmanship for the duration(s) described below.  This limited 

warranty DOES NOT cover machines and/or components subject to normal wear and tear, damage 

that occurs in shipping, failures resulting from modification, accident, unsuitable operating environ

-

ment, misuse, abuse, neglect, or improper maintenance by you.  For full details, contact your Autho-

rized Tornado Distributor, Service Center, or the Tornado Technical Service Department.  Tornado 

sales and service representatives are not authorized to waive or alter the terms of this warranty, or to 

increase the obligations of Tornado under the warranty.

Terms subject to change without notice

1.  Except all Windshears™ Blowers, Storm, TV2SS, Side and Downdraft, Insulation Blowers, CV 30, 

CV 38, CK14/1 PRO, CK 14/2 PRO, SWM 31/9, CK LW13/1, CK LW 13/1 ROAM, CV 38/48 Dual, 

PV6, PV10, PV6 ROAM, Wall Mount Vacuum and all chargers are warranted for 1 (one) year for both 

parts and labor.

2.  All non-wear item parts purchased after warranty expiration are warranted for 90 days.

3.  Warranty starts from the date of sale to the consumer or, at Tornado’s discretion, 6 months after 

the dealer purchased the unit from Tornado, whichever comes first.

4.  The EB 30 is warranted for a period of 90 days for both parts and labor.

5.  The warranty on engines used on propane powered equipment is limited to motor manufacturer’s 

warranty.

6.  Ride-on Scrubbers are warranted for 24 months, parts, 6 months labor or 1,000 hours, whichever 

occurs first.

Note:

 Tornado, The Latest Dirt, Floorkeeper, 

Carpetkeeper, Carpetrinser, Carpetrinser/Dryer, 

Headmaster, Taskforce, PAC-VAC, T-Lite, Glazer, 

Windshear, Max-Vac and Trot-Mop are trademarks 

of Tornado Industries

Website: www.tornadovac.com

Phone 1-800-VACUUMS

Fax 817-551-0719

Address 3101 Wichita Court

Fort Worth, TX 76140

Form F2662.©2017.  All rights reserved

1-800-VACUUMS   

 

90 Years of Cleaning Innovation 

A Tacony Company 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание 97130

Страница 1: ...0719 WWW TORNADOVAC COM Operations Maintenance Manual For Commercial Use Only Form No L7130AB 01 17 Tornado Industries LLC All rights reserved 8 lb Lightweight Vacuum MODEL NO 97130 115V 97131 230V h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Страница 2: ... 1 Except all Windshears Blowers Storm TV2SS Side and Downdraft Insulation Blowers CV 30 CV 38 CK14 1 PRO CK 14 2 PRO SWM 31 9 CK LW13 1 CK LW 13 1 ROAM CV 38 48 Dual PV6 PV10 PV6 ROAM Wall Mount Vacuum and all chargers are warranted for 1 one year for both parts and labor 2 All non wear item parts purchased after warranty expiration are warranted for 90 days 3 Warranty starts from the date of sal...

Страница 3: ...erial number here ________________________________ MODEL NO 97130 97131 VOLTS 115 230 SERIES LW 13 1 LW 13 1 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Страница 4: ...bt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in sketch A Your new Tornado unit is a high quality precision made product All parts used in t...

Страница 5: ...e is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not pull or carry by cord use cord as handle close a door on cord or pull cord around sharp edges or corners Do not run appliance over cord Keep cord away from heated surfaces Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or applian...

Страница 6: ...twin fan dual suction design for deeply embedded dirt and superior edge cleaning 15 Rotating Cleaning Brush continuous rotating dual action for thorough cleaning white non mar ring bristles 16 Non Marring Wheels safe for use on bare floors 17 Soft Furniture Protection Guard helps protect furniture while vacuuming 18 Hair Cutter ensures that any long hair or other fibers are cut and broken down int...

Страница 7: ...7 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Страница 8: ...t caught in the Dust Tube Power Supply The Power Cord is stored at the back of the vacuum cleaner and is looped around the Quick Release Cord Hooks The polarized Power Source Plug is designed to attach to the Power Cord during storage Before using make sure the Connector Plug is securely attached to the Powerfoot and that the Power Source Plug is plugged into a polarized outlet Power Switch The Po...

Страница 9: ...uum features Dust Tube designed to optimize cleaning power For best performance routinely check and clear excess dust and other debris Note Cover floor with newspaper to catch any loose material or dust removed during cleaning Release Bag Tension Spring Remove Filter Cover screw and then remove Filter Cover Unplug Connector Plug Locate the Tube Release Button at the top of the Powerfoot The Tube R...

Страница 10: ...h and replace Drive Belt WARNING To avoid electrical shock or injury from moving parts always turn OFF the Power Switch and unplug the Power Source Plug before perform ing maintenance or trouble shooting Always unplug by grasping the Power Source Plug NEVER pulling on the Power Cord to unplug 5 To remove the Rotating Cleaning Brush pull the right side of the Rotating Cleaning Brush toward the fron...

Страница 11: ...s full Drive Belt not functioning Rotating Cleaning Brush bristles worn Rotating Cleaning Brush jammed Dust Tube is clogged Replace with new Dust Bag Realign Drive Belt or replace if damaged Replace Rotating Cleaning Brush Remove Rotating Cleaning Brush and clean de bris from brush ends Reinstall Drive Belt Clean Dust Tube Accumulation of dust inside Cloth Bag Possible Cause Remedies Dust Bag is c...

Страница 12: ...e feet meters Total Hard Floor Area Total Carpeted Area Square feet square meters o Contacted by local dealer o Previous experience with Tornado products o Reputation Recommendation o Advertising o Direct mail o Internet o Other o 0 10 000 0 930 o 10 50 000 930 4 650 o 50 250 000 4 650 23 250 o Over 250 000 over 23 260 o 0 10 000 0 930 o 10 50 000 930 4 650 o 50 250 000 4 650 23 250 o Over 250 000...