7
ASSEMBLY OF THE UNIT
1. Remove all components from packaging
2. The venturi powerhead(s) come already at-
tached to the Jumbo cover adaptor(s). To
detach, remove the external filters from the
venturi powerhead(s), then turn powerhead(s)
counterclockwise and they will unlock from the
Jumbo cover adaptor. When attached, Make
sure exhaust nozzles(s) face outward.
3.
Install external filter support rod(s) by placing
them in access hole(s) located in the Jumbo
cover.
4.
Attach external filter(s) by attaching to filter
support rod(s) and installing inlet collars onto
exhaust nozzle(s). Turn collar(s) clockwise to
lock. Do not twist filter.
5. Install hose adaptor into Jumbo housing.
Lock in place by lining up adaptor indent with
lock screw and tightening lock screw.
6. Place Jumbo cover assembly onto drum. The
weight and suction power of the Jumbo cover
assembly will form a seal onto the drum
STARTING/STOPPING OF MACHINE
1. Connect air supply line to head line connector.
2. Start Vacuum by turning air valve located on
line connector to the ON position.
3. Stop vacuum by turning air valve located on
line connector to the OFF position.
OPERATING RULES
Use 1.5” or 2” I.D. hoses and attachments
Use 1/2” (Single) and 3/4” (Dual) air line hose
and flow through connectors (do not use ball style
fittings).
Use 90 p.s.i. (7 BAR) at gauge (valve open) for
maximum pickup power, 60 p.s.i. (5 BAR) at
gauge (valve open) for lighter debris
Never operate over 100 p.s.i. (8 BAR).
Use to recover water, heavy oils, powder, grind-
ings, and metal shavings.
Hearing protection must be worn when operating
these units.
Grounding and static discharge are requited
when recovering powders. Use Tornado static
conductive hoses (Urethane or Neoprene), and
aluminum tools. Ground vacuum head and tank
assembly to an earth ground.
MAINTENANCE
EXTERNAL FILTER
For maximum operating efficiency and to ensure
longer wear, remove filter(s) and empty by de
-
taching the bottom clamp after every use
ALL OTHER MAINTENANCE
Empty and clean vacuum filter(s) and attach
-
ments after each days use for maximum perfor-
mance
https://harrissupplyind.com - To Order Parts Call 608-268-8080