3.1 GENERAL SITE AND SPACE REQUIREMENTS
When choosing a location for your machine, you must verify
that it meets all requirements outlined in this section.
3.1.1 Site Requirements
You must verify that the area:
l
Allows for unrestricted access to machine controls.
l
Conforms to the following:
o
Primary Power Required
Single-Phase 230 Vac,
50/60 Hz
o
Recommended Circuit Amperage
20 A breaker
Note:
For more information, see "Electrical and
l
Has a fire extinguisher within the work area.
l
Provides for unobstructed machine motion and
operation.
3.1.2 Space Requirements
The area must meet the following space requirements. Allow
more space to access the rear of the machine for maintenance
and repairs.
l
Machine Size
78" x 70" (1.95m m x 1.7 m)
l
Machine Height
55" (1.4 m)
Figure 3-1: Dimensions of the machine itself, as
viewed from the front.
l
Typical System Footprint
89" × 67" (2.3 m × 1.7 m)
Figure 3-2: Dimensions of the machine and it's
required added space, as viewed from above.
3.2 ELECTRICAL AND POWER REQUIREMENTS
You must verify that the site conforms to the following
electrical and power requirements.
3.2.1 Electrical Requirements
A certified electrician must make all electrical connections,
and it's your responsibility to verify that the electrical
installation of the machine meets all local regulations and
electrical codes.
l
Primary Power Required
Single-Phase 230 Vac, 50/60
Hz
l
Recommended Circuit Amperage
20 A breaker
3.2.2 Power Requirements
If the site conforms to the electrical requirements, verify that
it meets the following power requirements:
l
Proper Grounding
You must properly ground the
power input to the machine. Examine the continuity
between bare metal on the machine frame and true
earth ground (a water pipe or similar) to verify that it's
properly grounded.
l
Correct Plug Pattern
The machine is shipped with a
NEMA 6-20P plug, designed for use with a NEMA 6-20R
receptacle.
3.2.3 Plasma Source Power Requirements
In addition to the requirements listed above for the machine
itself, make sure that you have a separate circuit available to
power your plasma source. For example, when using 220V
©Tormach® 2020
Specifications subject to change without notice.