feed  back  the  filtrate  water  from  the  backwashing  tank  to  the  membrane 

module.    During  backwash,  chemical feed  pump  can  be  operated to  dose 

chemical  to  the  backwash  water.    The  dosing  chemical  is  usually  sodium 

hypochlorite and the dosing ratio should be up to 50 mg/L as Cl

2

The  flow  rate  of  backwash  water  is  set  up  in  advance  for  1.0  to  1.5  times 

filtrate  water  flow  rate  (Do  not  exceed  Max.  Backwash  Flow  described  in 

Table 4). 

(4)  After backwashing for a fixed time (normally 30 seconds, up to 60 seconds), 

close the backwashing valve (V-6) and stop the backwashing pump. 

(5)  Open  the  air  exhaust  valve  (V-4)  and  the  air-scrubbing  valve  (V-2)  for 

air-scrubbing for a fixed time (normally 30 seconds, up to 60 seconds). 

 

 

 

The air flow rate for air-scrubbing should be within 

the  range  below.    Excessive  air  flow  rate  may 

damage the hollow fiber membrane. 

HFU-2020HN: 4.8 

– 9.0 Nm

3

/h, normally 6.0 Nm

3

/h 

(2.8 

– 5.3 scfm, normally 3.5 scfm) 

The  maximum  required  air  pressure  during  the 

air-scrubbing for inside of the module will be 40 kPa 

(6 PSI). 

 

(6)  Close the air-scrubbing valve (V-2) and open the drainage valve (V-3). 

(7)  Close the drainage valve (V-3) after the water is all drained out. 

(8)  Run the feed water pump and open the feed water valve (V-1). 

(9)  Close the air exhaust valve (V-4) after the air is purged from the module. 

 

 

 

 

Содержание TORAYFIL HFU-2020HN

Страница 1: ...iber Membrane Module TORAYFILTM Instruction Manual Model HFU 2020HN type HN issued by Toray Industries Inc Water Treatment Environment Division 2 1 1 Nihonbashi Muromachi Chuo ku Tokyo 103 8666 Japan...

Страница 2: ...4 Safety Instruction for Disposal 9 III Specifications of Toray HFU 2020HN Membrane Module 10 IV Configuration of Toray HFU 2020HN Membrane Module 13 V Installation 14 VI Operation 17 1 Filtration 17...

Страница 3: ...is suitable for high turbidity water treatment because the air scrubbing can be adopted to remove suspended solid effectively 1 Characteristics of Toray HFU series Membrane Modules 1 High Filtration...

Страница 4: ...entrations of acid resulting in better cleaning and longer sustainable membrane flux rates 2 About type HN Type H is a module type which allows high pressure 600 kPa operation Type N is a module type...

Страница 5: ...ous situation which will result in serious injury or death when the instruction is not observed This symbol indicates a potentially hazardous situation which will result in serious injury or death whe...

Страница 6: ...rt with sufficient amounts of clean running water for more than 15 minutes and see the doctor immediately Be sure to wear safety gear such as a helmet and safety shoes to avoid injury The preservative...

Страница 7: ...g Follow the instruction of the Housing Type Joints Set up Guide at the connection point Wrong connections may damage the modules Keep the connection surface free of any dirt or oils Be sure to instal...

Страница 8: ...Air left in the modules may cause water hammer and may result in damage to the membrane Prior to use make certain modules are flushed Filtrate water should be drained unless it meets the required qual...

Страница 9: ...manual Do not overfeed air to the modules Excessive scrubbing air damages the membranes and or shortens the membrane life The air flow rate should be within the range below for each module type HFU 20...

Страница 10: ...contacted part appropriately based on the SDS Do not mix sodium hypochlorite with acid Such mixture generates toxic chlorine gas Stop operation whenever any anomaly occurs with the equipment or any si...

Страница 11: ...s please apply a service of a qualified waste disposing company When the module is to be incinerated please apply the appropriate facilities in which hydrogen fluoride HF gas can be neutralized HF gas...

Страница 12: ...below 300 kPa 43 5 PSI at any time even during the filtration Table 2 Feed water limits 1 Turbidity Intermittent Peak 4 Standard 100 NTU Potential 5 200 NTU Continuous Maximum Standard 30 NTU Potenti...

Страница 13: ...ter Surface 72 m2 775 ft2 Dimensions Diameter 216 mm 8 50 inches Length 2 160 mm 7 087 ft Weight Full of Water 110 kg 243 lbs Drained 67 kg 148 lbs Materials Housing PVC and or equivalent Potting Epox...

Страница 14: ...12 Handle and operate the modules within the ranges and the limits indicated in Table 1 to 4 Operation out of these ranges or limits may damage the modules and affect filtration performance...

Страница 15: ...of Backwash Water 2 Air Outlet Backwash Water Outlet 3 Feed Water Inlet Air Inlet Drain Outlet Connections Pipe fitting outer diameter mm in Connectors 1 89 1 3 1 2 Housing type joint 80A 2 76 3 3 Ho...

Страница 16: ...ochlorite solution 100 mg L of chlorine If this solution splashes onto your skin wash the affected part with running water If the solution gets in your eyes or mouth wash the affected part with enough...

Страница 17: ...n the right direction Do not overtighten the module with the hanging hook and or the supporting belt or you may damage the module Do not allow the hollow fiber membranes to dry even for a few hours es...

Страница 18: ...he instruction of the Housing Type Joints Set up Guide when using Housing Type Joints A wrong use may cause the damage to the module 6 Air inject should be located just beneath the bottom nozzle of th...

Страница 19: ...example of piping 2 Make sure the feed water valve V 1 the drainage valve V 3 and the valve for the scrubbing air V 2 are closed 3 Make sure the filtrate water line is open Open the air exhaust valve...

Страница 20: ...riate volume of filtrate water flow Do not exceed 600 kPa 87 0 PSI to avoid damage to the module Operating conditions including the filtration flux and the physical cleaning should be properly set up...

Страница 21: ...nutes normally for surface water filtration Please contact us if you need technical support Fig 4 shows a typical example of the flow diagram for backwash and air scrubbing Do not carry out the backwa...

Страница 22: ...op the backwashing pump 5 Open the air exhaust valve V 4 and the air scrubbing valve V 2 for air scrubbing for a fixed time normally 30 seconds up to 60 seconds The air flow rate for air scrubbing sho...

Страница 23: ...and stop the operation if abnormal water quality is detected If abnormal water quality is detected check the integrity of the element with PDT Pressure Decay Test or DAF Diffusive Air Flow Test The te...

Страница 24: ...alled Toray Maintenance Cleaning TMC The TMC is usually held following the backwash and air scrubbing which does not contain the chemical dosing The frequency and soaking time of the TMC mainly depend...

Страница 25: ...mp close the backwashing valve V 6 and stop the backwashing pump 5 Soak the membrane in the chemical for a fixed time normally 20 minutes And then open the air scrubbing valve V 2 for a fixed time nor...

Страница 26: ...required water quality 9 Make sure the air scrubbing valve V 2 and the backwashing valve V 6 are closed and the backwashing pump is stopped Constantly monitor filtrate water quality during filtration...

Страница 27: ...s Membrane Pressure TMP it is necessary to involve the height difference of inlet and outlet pressure gauges Example calculation of TMP TMP Pin Hin Pout Hout 70 10 20 25 60 45 15 kPa Note the followin...

Страница 28: ...degree C corrected TMP with multiplying by TCF at real temperature shown in Fig 6 A filtrate flow rate measured at some real temperature can be converted to 25 degree C corrected filtrate flow rate wi...

Страница 29: ...If you use the unacceptable chemicals or perform the cleaning altered from the recommended procedure the membrane could be seriously damaged Pay full attention when handling chemicals and be sure to w...

Страница 30: ...us if you need the information in detail 2 Open the chemical return valve and then open the chemical feed valve 3 Run the chemical feed pump to start the circulation of chemical and then open the chem...

Страница 31: ...amaged and or the life of membrane may be shortened The cleaning temperature should be 20 to 40 degree C The circulation flow rate for each type of the module is as follows HFU 2020HN 50 L min 13 gpm...

Страница 32: ...or rinsing and make sure that pH of the water in the module is in the range between pH 6 5 and 7 5 after rinsing Do not use any other chemicals than those indicated above Do not mix sodium hypochlorit...

Страница 33: ...ary shutdown or storage In the case of the suspension of operation for less than four days stop the feed water and keep modules full of water Keep the modules at 0 to 40 degree C If the suspension las...

Страница 34: ...od Preservative Chemical Concentration of the Chemical More than 7 days Sodium bisulfite 1 000 mg L Rinse the module thoroughly with clean water after the chemical cleaning with sodium hypochlorite an...

Страница 35: ...herein or the safety and the compatibility of this product Before using this product the user is asked to check for its safety and compatibility with the intended purpose The content of this Instructi...

Отзывы: