background image

Tentative release: 2016-06-21 

SPECIFICATIONS

 

 
 
 
Frequency range: 

 

430MHz – 460 MHz 

 

 

 

 

 

Mode:  

 

 

Selectable AM/FM or SSB 

 
RF output power: 

 

Selectable in 4 steps: 

 
 

 

 

 

LOW:   

 

25Watt 

 

 

 

 

MEDIUM: 

 

50 Watt 

 

 

 

 

HIGH:  

 

100 Watt 

 

 

 

 

SUPER: 

 

>100 Watt (limited to 120 Watt typ.) 

 
 
RF input power: 

 

Maximum: 

 

8 Watt 

 
 

 

 

 

(Exceeding maximum limit will trigger OVERDRIVE 

 

 

 

 

protection, PA operation will be denied) 

 
 

 

 

 

Recommended:   

2Watt <Pin <5 Watt 

 
 
RF input power,   
PA not active (bypass): 

Maximum: 

 

50 Watt, <50% duty cycle 

 
 
DC supply voltage:   

Minimum:     

10.5 V 

 

 

 

 

Maximum:     

14.5 V 

 

 

 

 

(Outside above limits, PA operation will be denied) 

 
 

 

 

 

Recommended: 

13.6 V 

 
 
DC supply current 
during transmission:   

Maximum: 

 

24 Amp 

 
 

 

 

 

Typical (f=450 MHz): 

 
 

 

 

 

LOW:   

 

9.5   

Amp 

 

 

 

 

MEDIUM: 

 

13.5 

Amp 

 

 

 

 

HIGH:  

 

19.5 

Amp 

 

 

 

 

SUPER: 

 

21.0 

Amp 

 

Содержание PA-100U-5

Страница 1: ...Tentative release 2016 06 21 Instruction Manual UHF 450MHz Band 100W Power Amplifier Model PA 100U 5 TOPTEK ...

Страница 2: ...of band signals is included Multi function digital meter allows instant verification of Output RF power Input RF power antenna SWR DC supply voltage and chassis temperature Multipath Automatic Level Control ALC provides reliable output power control and amplifier damage protection Output power is selectable between 4 available pre programmed levels Multiple protection features enhance system relia...

Страница 3: ...aximum 8 Watt Exceeding maximum limit will trigger OVERDRIVE protection PA operation will be denied Recommended 2Watt Pin 5 Watt RF input power PA not active bypass Maximum 50 Watt 50 duty cycle DC supply voltage Minimum 10 5 V Maximum 14 5 V Outside above limits PA operation will be denied Recommended 13 6 V DC supply current during transmission Maximum 24 Amp Typical f 450 MHz LOW 9 5 Amp MEDIUM...

Страница 4: ...e release 2016 06 21 Bypass mode insertion loss typ 1 dB RX preamplifier gain typ 10 dB 450 MHz RX preamplifier noise fig typ 3 5 dB 450 MHz RF connectors type N 50 Dimensions 183 W 78 H 280 D mm Weight 2 8 Kgs ...

Страница 5: ...nt Watt SWR Load SWR measurement Unitless DC VOLT DC voltage measurement Volts TEMP Chassis temperature measurement Degrees Celsius 3 POWER LEVEL SELECTION Button toggles between various power levels LOW Pmax 25Watt MEDIUM Pmax 50Watt HIGH Pmax 100Watt SUPER 100Watt Pmax appr 120Watt 4 BOOSTER MODE SELECTION Button toggles between 3 modes of power amplifier operation IDLE READY and SSB LEDs are bl...

Страница 6: ...eter animates scrolls the information about RF power and center frequency Po 100 Fr 430 460 7 WARNING LEDs OVERDRIVE Indicates excessive drive power 8W HIGH SWR Indicates excessive SWR Depending on actual SWR value TX mode will be denied or allowed with limited output power DC VOLT Indicates DC voltage being outside operating range 10 5V to 14 5V TX mode will be denied TEMP Indicates excessive cha...

Отзывы: