CHAPTER 5
–
CONNECTING FIELD DEVICES TO THE I/O BOARD
51
MultiLoad II/ RCU II Explosion Proof Lite (EXL) Installation Guide - Part # 6070
MultiLoad II Lectro Count Remote Display Wiring
I/O DIGITAL/
ANALOG
I/O 2 METER
METER 0
METER 1
PORT 11/
PORT 0.10
+
-
5
– 28 Vdc
PORT 1.10
+
-
+
-
PORT 1.10.OUT
PORT 1.10.IN
PORT 11.OUT/
PORT 11.IN/
IN
1
✓
OUT 2
✓
IN
3
✓
OUT 4
✓
IN
5
OUT 6
IO_DA TB3
PORT 10
PORT 11
PORT 12
PORT 10/
PORT 0.10.OUT
PORT 0.10.IN
PORT 10.OUT/
PORT 10.IN/
IN
1
✓
OUT 2
✓
IN
3
OUT 4
IO_2M TB9
PORT
0.10
IN
1
OUT 2
IN
3
✓
OUT 4
✓
IO_2M TB9
PORT
1.10
≥ 500 mA
RESET
12 V COM
COUNT +
12 Vdc
Note:
Use only model E1613. The Lectro Count +12Vdc, 12V common can be supplied by an external source.
Note (I/O DIGITAL/ ANALOG Only):
Connect Port 10 to Lectro Count output pulse. Connect Port 11 to Lectro Count reset pulse.
Note (I/O 2 METER Only):
Connect Port 0.10 to Lectro Count output pulse. Connect Port 1.10 to Lectro Count reset pulse.