background image

C30S

INSTALLATION AND USE INSTRUCTIONS 

CHAIN ACTUATOR FOR
WINDOW AUTOMATION

PATENTED

BEFORE INSTALLING AND USING THE ACTUATOR, IT IS 

COMPULSORY FOR THE INSTALLER AND THE USER TO READ

 AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS.

THIS MANUAL IS INTEGRAL PART OF THE ACTUATOR 

AND MUST BE PRESERVED FOR FUTURE REFERENCE 

UNTIL DEMOLITION OF THE SAME. 

VER.0.0

REV.02.18

P/N 0P5311

original instructions

Содержание C30S/230V

Страница 1: ...ALLING AND USING THE ACTUATOR IT IS COMPULSORY FOR THE INSTALLER AND THE USER TO READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS THIS MANUAL IS INTEGRAL PART OF THE ACTUATOR AND MUST BE PRESERVED FOR FUTURE REFERENCE UNTIL DEMOLITION OF THE SAME VER 0 0 REV 02 18 P N 0P5311 original instructions ...

Страница 2: ......

Страница 3: ...Limits page 11 3 7 Package page 11 4 SAFETY 4 1 General instructions page 13 4 2 Safety Devices page 13 4 2 1 Protections against electric hazard page 13 4 3 Safety plates page 14 4 4 Residual risks page 14 5 INSTALLATION 5 1 General instructions page 15 5 2 Top hung windows page 18 5 3 Bottom hung windows page 19 5 4 Electrical Connections page 20 5 5 Control devices page 21 5 6 Emergency procedu...

Страница 4: ...mity with the all the relevant provisions of the following directives including all applicable amendments EMC Directive 2014 30 EU RoHS II Directive 2011 65 EU The following harmonised standards have been applied EN 60335 2 103 2015 applicable parts EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 2015 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 AC 2012 EN 50581 2012 and the following technical document...

Страница 5: ...ANUAL AND IF IT IS USED WITH NON GENUINE PARTS ACCESSORIES SPARE PARTSAND OR CONTROL FEEDING UNITS 2 2 INSTALLER AND USER THE ACTUATOR INSTALLATION CAN BE PERFORMED EXCLUSIVELY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION THE INSTALLATION TECHNICIAN SHALL ACCEPT FULL RESPONSIBILITY...

Страница 6: ...RIVING FROM FAILURE TO OBSERVE THE ABOVE REQUIREMENTS Specialised electrician A specialised electrician must be able to install the actuator start it and operate it both in normal conditions and in the maintenance mode he she is qualified to perform all electrical and mechanical adjustment and maintenance operations He she is allowed to work on live electrical cabinets and junction boxes User spec...

Страница 7: ...t is applied externally on the actuator The plate bears in readable and indelible way the following data logo and address of the manufacturer type and model voltage and intensity of power supply V A type of service S min 2 absorbed electric power P W thrust and tractive force F N idle translation speed mm s protection degree IP symbol of double insulation only for mod C30S 230V CE marking symbol o...

Страница 8: ...ing stroke adjustment switch I 200 mm II 380 mm 5 Connection bracket to the frame 6 Actuator 7 Chain adjustment end 8 Chain end adjustment screw 9 Power supply cable 8 C30S 3 TECHNICAL DESCRIPTION INSTALLATION AND USE ISTRUCTIONS Fig 1 7 8 6 80 335 2 101 3 103 96 5 6 5 1 5 34 12 20 11 Ø5 Ø5 11 54 19 4 2 1 16 86 15 4 49 37 46 53 46 9 5 1 12 12 7 310 276 ...

Страница 9: ...TH BRACKETS 1 1 kg GROSS WEIGHT 1 5 kg SYNCHRONIZ TWO ACTUATORS ON THE SAME WINDOW Yes POWER SUPPLY VOLTAGE 230 V 50 Hz 24 V 10 ABSORBED CURRENT 0 15 A 0 55 A ABSORBED POWER WITH LOAD 25 W 14 W PROTECTION AGAINST ELECTRIC SHOCKS Class II Class III PROTECTION DEGREE OF ELECTRIC DEVICES IP30 PARALLEL CONNECTION OF MORE THAN ONE ACTUATOR Yes See wiring diagram ADJUSTABLE STROKES ON OUTLET 200 mm 380 ...

Страница 10: ...l unit just connect the yellow white blue cables as per wiring diagram at the back of the manual to achieve the synchronized mode The Smart Reset System SAI has also been included which adjusts the closure of the window in an optimum manner The C30S chain actuator is mounted when you need two or more attachment points because the window is particularly heavy or wide and only one actuator would not...

Страница 11: ...TMOSPHERIC AGENTS RAIN SNOW ETC THE USE OF THE ACTUATOR IN ENVIRONMENTS WITH POTENTIALLY EXPLOSIVE ATMOSPHERE IS STRICTLY FORBIDDEN IT IS COMPULSORY TO KEEP THE PACKAGE AND THE ACTUATOR OUT OF REACH OF CHILDREN 3 7 PACKAGE STANDARD Each standard package of the product cardboard box contains Fig 4 No 1Actuator equipped with power supply cable No 1 Window frame connection bracket Ref A No 1 Bracket ...

Страница 12: ...12 C30S 3 TECHNICAL DESCRIPTION INSTALLATION AND USE ISTRUCTIONS A F D Fig 4 E B C ...

Страница 13: ... PARTS OR COMPONENTS OF THE ACTUATOR OR THE USE OF UNORIGINAL ACCESSORIES AND CONSUMABLES MAY INCREASE THE RISK OF ACCIDENT AND THUS RELIEVES THE MANUFACTURER OF ALL CIVILAND PENAL LIABILITY EXTRAORDINARY AND ROUTINE MAINTENANCE OPERATIONS INVOLVING THE TOTAL OR PARTIAL DISMOUNTING OF THE ACTUATOR MAY ONLY BE PERFORMED AFTER DISCONNECTING IT FROM THE POWER SUPPLY THIS APPLIANCE MAY NOT BE USED BY ...

Страница 14: ...actuator has been installed on the window the actuator drive can accidentally generate the following residual risk Residual risk Hazard of squashing or dragging of body parts inserted between the movable and the fix part of the window frame Exposure frequency Accidental and when the installer or the user decides to perform a wrong voluntary action Severity of the damage Light lesions usually rever...

Страница 15: ...RMING THE INSTALLATION OF THE ACTUATOR ON HOPPER WINDOWS VERIFY THAT ON BOTH SIDES OF THE WINDOW TWO COMPASS STROKE LIMIT DEVICES ARE INSTALLED IN ORDER TO AVOID THE ACCIDENTAL FALL OF THE WINDOW FOR CORRECT OPERATION OF THE ACTUATOR THE WINDOW FRAME MUST HAVE A MINIMUM HEIGHT DISTANCE OF THE ACTUATOR FROM THE WINDOW OPENING HINGE EQUAL TO THE VALUES QUOTED IN TAB 1 VERIFY THE DIMENSION D VARIABLE...

Страница 16: ...OWER THAN 500 mm IT IS SUGGESTED TO ADJUST THE STROKE 200 mm SWITCH POS I A THE POSITIONS 1 2 3 0 ARE TO BE USED ACCORDING TO THE OVERLAPPED PART OF THE WINDOW D OVERLAPPED PART ACTUATOR POSITION TYPE OF APPLICATION TOP HUNG 5 INSTALLATION INSTALLATION AND USE ISTRUCTIONS Dimensions in mm Fig 6a Frame Wing Standard 0 Pos DIMENSION D VARIABLE BETWEEN 0 TO 50 mm A 2 3 0 D 10 1 53 49 24 7 5 7 5 7 5 6...

Страница 17: ...ROKE MIN WINDOW LIGHT OPENING ANGLE MOTOR OVERALL DIMENSIONS B 200 mm 500 mm 22 39 5 mm 380 mm 900 mm 24 5 41 5 mm 17 C30S INSTALLATION 5 THE POSITIONS 1 2 3 0 ARE TO BE USED ACCORDING TO THE OVERLAPPED PART OF THE WINDOW TOP HUNG see Fig 28 INSTALLATION AND USE ISTRUCTIONS Dimensions in mm Fig 6b DIMENSION D VARIABLE BETWEEN 0 TO 50 mm Wing Frame 54 7 5 18 5 3 53 50 40 6 1 55 39 85 8 12 5 2 3 0 C...

Страница 18: ...oke using the switch Ref 1 on the right side of the actuator according to the door opening for tandem installations the actuators must have the same stroke CAUTION VERIFY THAT THE SELECTED STROKE IS SOME CENTIMETRES LOWER THAN THE STROKE EFFECTIVELY ALLOWED BY MECHANICAL LOCKS COMPASS LIMIT DEVICES OR WING OPENING HINDRANCES 7 Hook the system up electrically as indicated in par 5 4 and the wiring ...

Страница 19: ...ng and closing After the closing phase verify that the chain end is completely returned in its seat 5 3 BOTTOM HUNG WINDOWS Fig 9 and 22 29 1 Open the package par 3 7 and extract the various components 2 Fig 22 With a pencil draw the centre line Y of the window frame 3 Fig 23 Apply the template Ref 1 on the window frame aligning it with the previously drawn centre line Y CAUTION FOR NON COPLANAR W...

Страница 20: ...OLE OF THE ATTACHMENT BRACKET TO THE WINDOW FRAME 9 Fig 29 Connect the chain end to the bottom hung bracket 10 Repeat with the second actuator 11 Power up the actuators 12 Perform a test of complete window frame opening and closing After the closing phase verify that the chain end is completely returned in its seat 5 4 ELECTRIC CONNECTIONS Wiring diagram THE ELECTRIC CONNECTION OF THE ACTUATOR CAN...

Страница 21: ...R VERIFY THAT THE POWER SUPPLY CABLE IS NOT DAMAGED SHOULD IT BE DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR BY THE TECHNICAL ASSISTANCE SERVICE OR IN ANY CASE BYAUTHORIZED OPERATORS 5 5 CONTROL DEVICES THE CONTROL DEVICES USED TO DRIVE THE ACTUATOR MUST ASSURE THE SAFETY CONDITIONS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF USE According to the different type of installations the actu...

Страница 22: ...MAINS IN ORDER TO AVOID ANY UNEXPECTED START IF THE MAIN SWITCH CANNOT BE PADLOCKED IT IS COMPULSORY TO PLACE A SIGN FORBIDDING THE ENABLING IN SOME CASES THE EVENT OF POSSIBLE ANOMALIES MIGHT STALL ALSO OTHER ACTUATORS CONNECTED IN PARALLEL TO FIND THE SUPPOSED MALFUNCTIONING ACTUATOR RUN SOME CLOSING OPERATIONS IN SUCCESSION ABOUT 10 OPERATIONS EVERY 2 SECONDS TILL THE WORKING ACTUATORS START RU...

Страница 23: ...ORILY VERIFY THAT NEAR AND OR UNDER THE WINDOW THERE ARE NOT ANY PERSON ANIMAL AND THING WHOSE SAFETY MAY BE ACCIDENTALLY JEOPARDISED SEE PAR 4 4 DURING THE OPERATION OF THE ACTUATOR CONTROL DEVICE THE USER HAS TO COMPULSORILY OCCUPY A CONTROL POSITION ASSURING VISUAL CONTROL ON THE WINDOW MOVEMENT THE FUNCTION EFFICIENCY AND THE RATED PERFORMANCE OF THE ACTUATOR OF THE WINDOW FRAME ON WHICH IT IS...

Страница 24: ...NG THE INSTRUCTIONS FOR MAINTENANCE AND USE PROVIDED BY THE MANUFACTURER OF THE DEVICE AND BY THE COMPANY THAT CARRIED OUT THE INSTALLATION The use of the actuator allows to control automatically the opening and closing of the window according to the type of control device installed see par 5 5 6 2 SMART RESET SYSTEM SAI The Smart Reset System SAI is integrated into the software of the electronic ...

Страница 25: ...uries cracks discoloration etc the fixing systems brackets and screws are tight the window frame is not deformed and the seals are tight and check the cables and connectors The maintenance activity may be carried out either by TOPP in accordance with a specific agreement made with the user or by the installation technician or by other competent and qualified technical personnel in possession of al...

Страница 26: ...STRUCTIONS FOR A CORRECT OPERATION OF THE ACTUATOR D MUST HAVE A VALUE INCLUDED BETWEEN 0 mmAND 50 mm DOME ASSEMBLY BRACKET C30S 9 SPARE PARTS AND ACCESSORIES UPON REQUEST Fig 13 WING FRAME OVERLAPPED PART D MUST BE LOWER 50mm ...

Страница 27: ... INSTALLATION AND USE ISTRUCTIONS C30S INSTALLATION ON TOP HUNG WINDOWS X Fig 14 Fig 15 Fig 16 Fig 17 Fig 18 Fig 19 X DX I 200 mm II 380 mm 1 CAUTION both must have the same stroke in tandem installations ...

Страница 28: ...28 INSTALLATION AND USE ISTRUCTIONS C30S INSTALLATION ON TOP HUNG WINDOWS 1 Fig 20 Fig 21 1 3 2 DX SX DX ...

Страница 29: ...INSTALLATION AND USE ISTRUCTIONS C30S INSTALLATION ON BOTTOM HUNG WINDOWS Y Y Fig 22 Fig 23 Fig 26 Fig 27 Fig 24 Fig 25 Y I 200 mm II 380 mm 1 CAUTION both must have the same stroke in tandem installations ...

Страница 30: ...30 C30S INSTALLATION ON BOTTOM HUNG WINDOWS INSTALLATION AND USE ISTRUCTIONS 1 2 Fig 29 Wing Frame DIMENSION D VARIABLE BETWEEN 0 TO 50 mm Fig 28 D 0 ...

Страница 31: ...GRAMS 230 V 230V 50Hz 230V 50Hz 24V 24V C30S C30S A A C30S A C30S C30S A A C30S A BLUE YELLOW WHITE 4 5 6 BLUE YELLOW WHITE 4 5 6 4 5 4 5 6 BLUE YELLOW WHITE 4 5 6 BLUE YELLOW WHITE 4 5 6 24 V N L N L 6 4 5 5 6 4 6 4 5 5 6 4 6 GREY BROWN CLOSES OPENS CLOSES OPENS CLOSES OPENS Wiring diagram C30S DRAWINGS FOR INSTALLATION 1 2 3 1 2 3 BROWN GREY BLACK 1 2 3 LIGHTBLUE BROWN GREY BLACK 1 2 3 LIGHTBLUE...

Страница 32: ...TOPP S r l Società a Socio Unico soggetta a direzione e coordinamento di 2 Plus 3 Holding S p a Via Galvani 59 36066 Sandrigo VI Italia Tel 39 0444 656700 Fax 39 0444 656701 Info topp it www topp it ...