Typical Performance Characteristics
Horizontal Field of View (FOV)
Horizontal Field of View Diagram
The pole is positioned in the field of view of the sensor. The
sensor data stream is analysed for reliable detections of the
pole ( pole visible in every output frame). Two different sensor
configurations* are documented.
Setup for Horizontal FOV-Measurement
Sensor Position
Height
70 cm (27.5 in.)
Orientation
Sensor XY-plane parallel to ground
Target Pole
Height
100 cm (39.4 in.)
Diameter
Ø 75 mm ( 2.9 in.)
Sensor Configuration*
Area Color
Number of Pulses
Peak Window
Echo Rejection
Configuration 2
Dark gray
5
1
3
Configuration 3
Light gray
7
1
2
* Both configurations can be found as “Suggested Configurations” in the Toposens-Visualizer
⚠️
Blind Zone: This area is prone to false positives. Sensor outputs all detected points from 0 – 500 cm (0-197 in.)
⚠️
Configuration: Opening angle and max. detection distance dependent on configuration, target size and angle of reflection.
5
Preliminary Prototype | All right reserved | All Information without warranty
⚠️
Max. Detection Distance: Echoes from large orthogonal surfaces (e.g. walls) can be detected at 500 cm ( 197 in.)