GTalarm2
Application Note: Security, Alarm System
Monitoring, alarm, control.
This manual includes steps to install, set up and use your system.
Страница 1: ...GTalarm2 Application Note Security Alarm System Monitoring alarm control This manual includes steps to install set up and use your system...
Страница 2: ...PGM outputs 24V 1000mA Open Drain Digital expansion module BUS In field firmware upgrade via USB SERA Cloud Remote Service Events log buffer 2048 events Program remote controls using the master or ins...
Страница 3: ...or to the server 1 3 First steps to prepare GTalarm2 module and Sera2 software Preparation procedure of the module GTalarm2 Connect the GSM antenna to the antenna connector Insert the SIM card in the...
Страница 4: ...r supply Battery Wiring It is possible to supply the security system from stabilized power supply source 10 15 V and not less than 1 5A It is necessary to calculate max current of power supply The cur...
Страница 5: ...sed or used as security system s zones with selectable type NC NO EOL EOL TAMPER 2 programmable analog inputs I O1 I O2 0 10V 0 20mA that can be used or used as security system s zone with selectable...
Страница 6: ...Monitoring control via mobile phone web browser GTalarm2 Figure 5 Monitoring control via mobile phone web browser Figure 7 Monitoring via web mobile app Zone status 4 2 Monitoring via SERA2 software...
Страница 7: ...Application Note Security Alarm System www topkodas lt 7 E N Figure 8 Monitoring via free Sera2 software Zone status...
Страница 8: ...2012 configurable as encrypted and non encrypted Shock sensor Reporting to the central monitoring station GTalarm2 Figure 9 Reporting to the central monitoring station 4 4 Local alarm For protecting...
Страница 9: ...able analog inputs I O1 I O2 0 10V 0 20mA for analog sensors control or using as security system s zone with selectable type NC NO EOL EOL TAMPER 5 1 NC NO EOL detectors wiring It is recommended to us...
Страница 10: ...owing conditions If a Delay type zone is NOT violated during exit delay and a zone s with Stay attribute enabled exists the system will arm in Stay mode When arming the system in Stay mode under this...
Страница 11: ...xcept the module will auto bypass the zone if Armed in the Stay mode 6 Wiring Type Type EOL End of line resistor Input type with resistor NC Normal Close The alarm will be send when the circuit betwee...
Страница 12: ...ectors Figure 20 2 wire smoke detector wiring diagram o If I O1 I O2 set as 2 wire don t need connect 5 1k resistor to VD o I O1 I O2 do not have internal pull up resistors So if you want to connect N...
Страница 13: ...inuous signals generated and if the alarm system is disturbed pulse signal Signal is terminated by turning off the alarm system OFF ON Flash Open Command ARM Close Alarm Open Remote Control Output des...
Страница 14: ...nuous signals generated and if the alarm system is disturbed pulse signal Signal is terminated by turning off the alarm system 25 System State Output for connection of light indicator of the alarm sys...
Страница 15: ...arm the system and turn OFF the alarm by dialing the system s phone number from any of 800 available user phone numbers The system ignores any incoming calls from a non listed phone number The phone c...
Страница 16: ...smission Delay to enter a valid 4or 6 digits Security Code before the Central Monitoring Center CMS is notified If a valid Security Code is not entered within the 30 seconds then a message is sent to...
Страница 17: ...and press Start iButton RFID programming mode to start entering iButton keys 2 Press Stop iButton programming to stop entering iButton keys 3 Write configuration by pressing Write icon C by sending SM...
Страница 18: ...elow 9 2 Enter iButton keys by sending SMS message A Send SMS message to the module GTalarm2 INST123456 063 S INST Install Configuration of the parameters 123456 Installer s password Space character 0...
Страница 19: ...y In order to delete the code it is necessary to enter 000000000000 7 OUT The selected input will be switched if a user will call from this number Preferred input may be assigned to each user s number...
Страница 20: ...t is necessary to enter 000000000000 6 Keyb Code Key button code might be entered manually In order to delete the code it is necessary to enter 000000000000 7 OUT The selected input will be switched i...
Страница 21: ...er tamper recognition 18 Tamper Disable The module will not generate an alarm or trouble 19 Trouble when disarmed alarm as per zone when armed When disarmed Generates Trouble Only The module transmits...
Страница 22: ...d busy signal b The system will continue dialing the next listed user phone numbers in the priority order The system will dial again as many times as programmed and the same order as phone numbers lis...
Страница 23: ...tem can be configured to report events to the monitoring station by transmitting data messages to the monitoring station The system connects to the central monitoring station when the CMS Central Moni...
Страница 24: ...station to receive the connection requests TCP mode or the datagrams UDP mode transmitted by ALERT 2 Backup 1 Backup 1 central monitoring station settings 7 Transport Protocol TCP or UDP The used lin...
Страница 25: ...Code Format A 4 digit or 6 digit user access code format can be selected 6 I O1 Settings 2 Wire Smoke detector Fire current loop or 0 10V Analog Input Zone or Sensor or Output or 0 20mA 4 20mA Curren...
Страница 26: ...ton stops the monitoring of the module 3 IMEI IMEI number of GSM modem available in the module 4 SIM ICCID ICCID Integrated Circuit Card Identifier A SIM card contains its unique serial number ICCID I...
Страница 27: ...rm shutdown for the zone is activated Allowable number of the same alarm events is reached and the same events will not be reported 6 Bypassed If checked and the color is red the zone is bypassed 7 Fo...
Страница 28: ...seller with the questions about the configuration you have to Press Read icon first to read the configuration from the module the press File Save us and save the configuration Save the Events Log file...
Страница 29: ...l be taken to match sensor range to room size A sensor whose range extends well beyond the boundaries of the room is acoustically hot and vulnerable to false alarms For protecting glass on more than o...
Страница 30: ...icable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of eac...
Страница 31: ...ted on the other side of closed or partly open doors If warning devices sound on a different level of the residence from the bedrooms then they are less likely to waken or alert people inside the bedr...