1-9
DI: To Trigger Logic Level 0: 0~0.4V; Normal Logic Level 1:
3.3~30V
DO: To Trigger Logic Level 0: 0.1~0.6V; Normal Logic Level1:
2.4~5V
6.
Conduit Hole
These conduit holes are used for cables to go through.
7.
Zoom Lever
Move this lever to adjust the optical zoom. After adjusting, rotate
it clockwise to fix it.
8.
Focus Lever
Move this lever to adjust the Focus. After adjusting, rotate it
clockwise to fix it.
9.
Video DC level Adjustment
Rotate it adjust the overall lighting for this camera.
10. CCD Functions DIP-switch
11. Reset Button
Step 1:
Switch off IP device by disconnecting the power cable
Step 2:
Press and continue to hold the Reset Button. Reconnect
the power cable while continuing to hold the reset button.
Step 3:
Keep holding the reset button depressed around 6 seconds,
release the reset button. The unit will start up with factory default
settings.
PIN
NAME
DESCRIPTION
1
A_Out Audio Output
2
GND
Ground Pin
3
A_In
Audio Input
4
GND
Ground Pin
5
DO
Digital Output
6
GND
Ground Pin
7
DI
Digital Input
Item
Description
ON
OFF
AES
Auto Electric Shutter
Default
BLC
Backlight Compensation
Default
AGC
Auto Gain Control
Default
F.L.
Flickerless
Default