11
the gate operator installed.
DIP Switch #1–#2: Running time of the motor in
Midway Mode
DIP Switch #1: ON
– 2 Seconds
OFF
– 0
DIP Switch #2: ON
– 4 Seconds
OFF
– 0
NOTE: The midway mode function would be
disabled if both DIP switches are turned off.
Factory default setting is disabled. The midway mode could be activated by pressing button B of the
remote control when the gate is in the full closed position.
DIP Switch #3: Auto close function enabled/disabled
DIP Switch #3: ON
– auto close function enabled
OFF
–auto close function disabled
Important Note: When the auto close function is enabled, the photocell sensor is highly
recommended to be installed with the gate opener for safety.
DIP Switch #4: Left/Right open
2. Potentiometers
Potentiometer A and B are used to adjust the stall force and auto close time of the gate operator separately.
Turn
potentiometer A
clockwise to increase the stall force, and turn it counter-clockwise to decrease the
stall force.
Turn
potentiometer B
clockwise to increase the auto close time, and turn it counter-clockwise to decrease
the auto close time, the auto close time could be adjusted gradually from 1 to 99 seconds.
WARNING: Photocell is highly recommended to be installed with the gate opener as entrapment
protection for safety when you set stall force to maximum.
E.g. Running time of the operator in midway mode is 2 seconds.
E.g. Auto close function of the opener has been enabled. Factory default setting is disabled.