7. STANDARD ACCESSORIES
46
• Operating range by remote control:
Approx.200 m (656 ft.) (Though the pipe from a forward position)
Approx.25 m (82 ft.) (From above panel)
• The laser ON/OFF switch controls the laser beam only, not for the instrument. To turn power
OFF to the instrument, be sure to switch OFF the instrument after operation is finished. When
the laser is turned off by the laser ON/OFF switch, "STANDBY" is indicated on the display and
the laser flashes once for five seconds (standby mode).
• To turn the laser beam ON again after the laser is turned off by the remote control, wait for 2
seconds or more and then press the laser ON/OFF switch for 2 seconds or more.
• Large atmospheric motions could shorten the operating range by the remote control.
To prevent atmospheric motions from occurring, limit the working range within the shade or
use a blower (commercially-available) for working.