LS-B2 Operator’s Manual
W-1
Laser Systems, Inc.
LS-B2
Laser Sensor
Страница 1: ...LS B2 Operator s Manual W 1 Laser Systems Inc LS B2 Laser Sensor ...
Страница 2: ...alve hose and mechanical part is 90 days During the warranty period TOPCON will at its option repair or replace the product at no additional charge Repair parts and replacement products will be furnished on an exchange basis and will be either reconditioned or new This limited warranty does not include service to repair damage to the product resulting from accident disaster misuse abuse or modific...
Страница 3: ...o made the original sale Purchaser agrees to insure the product or assume the risk of loss in transit to prepay shipping charges to the warranty service location and to use the original shipping container or the equivalent A letter should accompany the package describing the problem and or defect ...
Страница 4: ...amages arising from the purchase or use of TOPCON Laser Systems Inc LS B2 or any performance hereunder or any claims of negligence even if TOPCON Laser Systems Inc has been advised of the possibility of such damages Service assistance can be provided by contacting your local TOPCON Laser Systems Inc dealer or by calling the Corporate Service Center Travel charges will be applied for any on site se...
Страница 5: ...Nomenclature 3 Installation 4 Mounting the System 4 Wiring the System 5 Maintaining Your System 6 Components 7 Operation 8 Operating the System 10 Grade Display Signals 14 Calibrating Valve Offsets 16 Calibrating Valve Gain 18 Setting On Grade Precision 20 LS B2 Battery Pack 21 ...
Страница 6: ... raise lower or on grade signal to the operator The operator then corrects the position of the cutting edge according to the signal In automatic control the LS B2 sends the signals directly to the machine s hydraulics which make the correction automatically The LS B2 transfers easily from machine to machine and offers the choice of on board batteries or machine battery powered operation The LS B2 ...
Страница 7: ...clature LS B2 NOMENCLATURE MOUNTING KNOB MOUNTING BRACKET PHOTO CELL RECEIVING WINDOW POWER BUTTON ON GRADE PRECISION OR MODE BUTTON DEAD BAND PRECISION INDICATORS GRADE INDICATE LED S CABLE CONNECTOR AND BATTERY PACK CLAMP CONNECTORS UNDERNEATH ...
Страница 8: ...K OF RD 2 Functions only when RD 2 LS B2 are Cable Connected DEAD BAND PRECISION INDICATORS IR 2 MOUNTING POSITION POWER ON OFF DEAD BAND PRECISION MODE CUTTING EDGE LOWER MODE AUTO CONTROL MODE GRADE INDICATE LED S MOUNTING BRACKET POWER CONNECTOR LS B2 CONNECTOR CUTTING EDGE RAISE MODE ...
Страница 9: ...0 44 45mm to 50 8mm in diameter or square pipes with sides from 1 5 to 1 95 38 1mm to 50mm ToMounton aMachineStick To mount the LS B2 on a backhoe or excavator you must first have a pipe attached to the machine stick Weld two brackets to your stick Bolt or otherwise attach your mounting pipe to the brackets Then clamp the LS B2 onto the pipe To Mount LS B2 A Close Bracket Over Pipe B Close Other H...
Страница 10: ...t as you clamp it to a pipe ToMounttheRD 2 Remote Display Using the head bolts and nuts supplied mount the RD 2 to either a vertical or horizontal surface in the cab Mounting LS B2 on a Motorgrader Mounting LS B2 on an Asphalt Paver To Mount LS B2 A Close Bracket Over Pole or Mast B Close Other Half of Bracket so Threaded Shaft w Centering Ball Sits Firmly in Slot C Turn Handle Until Tight HORIZON...
Страница 11: ...supply power from your machine s battery wire as shown Otherwise connect the LS B2 battery pack BT 39Q JC 4Cable 9060 5117 RD 2 LS B2 PC 18Cable 9060 5033 MACHINE BATTERY GROUND TO MACHINE FRAME PC 18 Cable 9060 5033 MACHINE BATTERY GROUND TO MACHINE FRAME LS B2 ...
Страница 12: ...0VAC or 230VAC Carrying Case 1 1 1 1 B Set Description Quantity LS B2 RD 2 PC 18 Power Cable 25 7 6m JC 4 Communication Cable Carrying Case 1 1 1 1 1 A Set Description Quantity LS B2 RD 2 IR 2 BT 39Q NiCad Pack Alkaline Holder PC 18 Power Cable 25 7 6m Adapter 12VDC 120VAC or 230VAC Carrying Case 1 1 1 1 1 1 1 Includes the IR RD 2 Adapter with the following parts Description Quantity Base M8 20mm ...
Страница 13: ...achine s cab so that the grade display signals are within easy view Grade signals become much easier to see when used with the RD 2 remote display When the RD 2 is connected to your machine s valves a switch on the front panel allows operators to select either manual or automatic control depending on the application Also the RD 2 features switches to manually raise or lower the machine cutting edg...
Страница 14: ... from the BT 39Q battery pack so no cords are necessary between the LS B2 and the RD 2 or between the LS B2 and the machine s battery LS B2 and Automatic Control Systems The LS B2 can be used as part of most Topcon automatic control systems By connecting the LS B2 to a Topcon control box and integrating it into the system the LS B2 helps provide high precision grade control to excavators graders p...
Страница 15: ...ipe Connect the LS B2 to the machine s battery with the cable or attach the BT 39Q battery pack and power on 4 Select the desired level of on grade precision from 1 for super high precision to 4 for very rough grading See page 20 for details NOTICE When cable connected the On Off Switch is disabled and the LS B2 is always on Cable SELECT LEVEL OF ON GRADE PRECISION BY PRESSING THE MODE BUTTON comm...
Страница 16: ...al bar across the center of its display 1 PLACE LS B2 ON BRACKET LOOSELY 2 MOVE LS B2 UP AND DOWN UNTIL ON GRADE SIGNAL APPEARS 3 TIGHTEN LS B2 TO BRACKET 6 Tighten the LS B2 firmly on its mounting pipe or pole To Operate with the RD 2 1 Set up and power on the rotating laser 2 Set your cutting edge at the desired elevation SET CUTTING EDGE AT DESIRED ELEVATION ...
Страница 17: ... RD 2 in the cab for easy monitoring then wire it to the machine s battery 5 Power on the RD 2 6 Press the on grade precision button on the RD 2 control panel to select the desired level of on grade precision from 1 for super high precision to 4 for very rough grading See page 20 for details HORIZONTAL MOUNT JC 4 Cable 9060 5117 PC 18 Cable 9060 5033 GROUND TO MACHINE FRAME MACHINE BATTERY RD 2 LS...
Страница 18: ...ghts if it is not receiving communication from the LS B2 If this occurs while you are using the infrared option an adjustment to the position of the IR 2 may be necessary ToUsetheRD 2 Automatic Controls If you or your dealer has connected the RD 2 to your machine s hydraulic valves you can switch from manual to automatic control and the reverse by pressing the RD 2 AUTO button 1 PLACE LS B2 ON BRA...
Страница 19: ...needed to reach grade The display consists of grade arrows if a correction is required and a horizontal bar signal when on grade Note which adjustments correspond to which grade indicate display signals TOO HIGH A LITTLE TOO HIGH ON GRADE A LITTLE TOO LOW TOO LOW LOWER CUTTING EDGE TO REACH GRADE SLIGHTLY LOWER CUTTING EDGE TO REACH GRADE SLIGHTLY RAISE CUTTING EDGE TO REACH GRADE RAISE CUTTING ED...
Страница 20: ...LS B2 Operator s Manual 15 Operating Notes ...