GENERAL HANDLING PRECAUTIONS

Before starting work or operation, be sure to check that the system is func-
tioning properly.

Affection of the radio waves

When using the instrument in the following place, the strong radio wave 
may cause faulty operation.
• Near the instrument occurring strong radio waves. (e.g. Transceiver)
• Near the radio wave towers such as television or radio.

Battery replacement

• Replace all 3 batteries with new ones at the same time. Do not mix 

used and new batteries, and do not mix different types of batteries 
together.

• Use alkaline dry cells. (3 Dry cells for initial operation check are com-

posed in a standard package.)
Nickel hydrogen dry cells and nickel cadmium dry cells can be used 
too, but the operating time is different from the time of alkaline dry 
cells.  

DISPLAY FOR SAFE USE

In order to encourage the safe use of products and prevent any danger to 
the operator and others or damage to properties, important warnings are 
put on the products and inserted in the instruction manuals.
We suggest that everyone understand the meaning of the following displays 
and icons before reading the “Safety Cautions” and text.

• Injury refers to hurt, burn, electric shock, etc.
• Physical damage refers to extensive damage to buildings or equipment and furni-

ture.

HANDLING PRECAUTIONS

Guarding the instrument against shock
When transporting the instrument, provide some protection to minimize risk 
of shock. Heavy shock may affect beam accuracy.

SAFETY CAUTIONS

Standard Set Composition

1 LS-B10 Instrument .................................................. 1pc.
2 AA-size dry cells...................................................... 3pcs.
3 Instruction manual................................................... 1pc.

Nomenclature and Functions

Operation

1

Mount the LS-B10 on the equipment and position a rotating laser.

2

Raise or lower the machine blade or arm to position the cutting 
edge or bucket at the desired grade elevation.

3

Turn on the LS-B10.

4

Keep the machine blade or arm motionless and raise or lower the 
LS-B10 and adjust until ON-GRADE position are flashing. This is 
the ON GRADE position. The reference position has been set.

5

While operating, use the LED display to continually check grade, 
moving the blade or cutting / filling according to the direction of the 
LS-B10 display.

Display

Meaning

WARNING

Ignoring or disregard of this display may lead to death or serious 
injury.

CAUTION

Ignoring or disregard of this display may lead to personal injury 
or physical damage to the instrument.

WARNING

• There is a risk of fire, electric shock or physical harm if you attempt to disas-

semble or repair the instrument yourself.

This is only to be carried out by TOPCON or an authorized dealer, only!

• Risk of fire or electric shock.

Do not use damaged power cable, plug and socket.

• Risk of fire or electric shock.

Do not use a wet battery.

• May ignite explosively.

Never use an instrument near flammable gas, liquid matter, and do not use in a coal 
mine.

• Do not hold the LS-B10 magnetic clamp near anyone who uses a pace maker 

or other electoronic medical devices.

The strong magnetic field can disrupt the normal operation of such devices.

• Battery can cause explosion or injury.

Do not dispose in fire or heat.

• The short circuit of a battery can cause a fire.

Do not short circuit battery when storing it.

CAUTION

Risk of injury to fingers.
Do not place fingers on magnet while mounting to equipment.

Strong magnetic field.
Do not place LS-B10 magnetic clamp near any sensitive electronic devices or mag-
netic storage media such as computer disk.

Do not allow skin or clothing to come into contact with acid from the batteries, if this 
does occur then wash off with copious amounts of water and seek medical advice.

EXCEPTIONS FROM RESPONSIBILITY

1) The user of this product is expected to follow all operating instructions and make periodic checks 

of the product’s performance.

2) The manufacturer, or its representatives, assumes no responsibility for results of a faulty or 

intentional usage or misuse including any direct, indirect, consequential damage, and loss of 
profits.

3) The manufacturer, or its representatives, assumes no responsibility for consequential dam-

age,and loss of profits by any disaster, (an earthquake, storms, floods etc.).
A fire, accident, or an act of a third party and/or a usage any other usual conditions.

4) The manufacturer, or its representatives, assumes no responsibility for any damage,and loss of 

profits due to a change of data, loss of data, an interruption of business etc., caused by using the 
product or an unusable product.

5) The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of 

profits caused by usage except for explained in the user manual.

6) The manufacturer, or its representatives, assumes no responsibility for damage caused by 

wrong movement, or action due to connecting with other products.

Indicator (LCD)

Battery cover knob

Battery cover

Please refer to the back of the instruction manual for the indicator display 
patterns.

Power switch

Power ON: Short push
Power OFF: Long push
LCD back light ON/OFF: Short push when 

power is ON 
(Auto turn-off after 
two minutes)

Detective precision (Mode) switch

Magnet

Buzzer sound switch

Buzzer sound: Quiet/Loud/OFF: Short push
LED ON/OFF: Long push

Indicator (LED)

Detector

Buzzer speaker