6-17
6 SPECIAL MODE (Menu Mode)
6.3 Setting Illumination of Display and Cross Hairs
Setting ON/OFF/LEVEL (1 to 9) for illumination of display (LCD) and reticle.
Setting LEVEL (1 to 9) is only for reticle.
[Example setting] LEVEL: 2 and turn on the illumination.
3
Press the [F3](YES) key.
4
Enter Elevation. *1)
Press the [F4](ENT) key.
[F3]
Enter ELEV.
[F4]
5
Enter Scale Factor in the same way.
Enter Scale
[F4]
Grid Factor is displayed for 1 to 2 second and
display returns to menu.
*1) Refer to Section 2.5 “How to Enter Alphanumeric characters”.
Input Range: Elevation : –9,999 to +9,999 meter (–32,805 to +3,2805 ft, ft+in)
Scale Factor: 0.990000 to 1.010000
Operating procedure
Operation
Display
1
After pressing the [MENU] key, press the [F4](P
↓
)
key to get the menu on page 2.
[MENU]
[F4]
2
Press the [F3] key.
The data previously set is shown.
[F3]
3
Press the [F3](LEVEL) key.
4
Press the [F2](
↑
) key, and then press the
[F4](ENTER) key.
[F3]
[F2]
[F4]
5
Press the [F1](ON) key.
[F1]
To return to previous mode, press the [ESC] key.
GRID FACTOR
ELEV.
=
1000 m
SCALE:0.999000
--- --- [CLR][ENT]
GRID FACTOR
ELEV.:2000 m
SCALE
=
1.001000
--- --- [CLR][ENT]
GRID FACTOR
=1.000686
MENU 2/3
F1:PROGRAMS
F2:GRID FACTOR
F3:ILLUMINATION P
↓
ILLUMINATION [OFF:1]
F1:ON
F2:OFF
F3:LEVEL
ILLUMINATION [OFF:1]
[LEVEL MODE]
↓
↑
––– ENTER
ILLUMINATION [OFF:2]
F1:ON
F2:OFF
F3:LEVEL
ILLUMINATION [ON:2]
F1:ON
F2:OFF
F3:LEVEL
Содержание GREEN LABEL GTS-250 Series
Страница 1: ...ELECTRONIC TOTAL STATION GTS 250 SERIES GTS 252 GTS 255 INSTRUCTION MANUAL 71014 90010...
Страница 2: ......
Страница 138: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Страница 139: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Страница 175: ...APPENDIX 4 APPENDIX...