2-6
2 PREPARATION FOR MEASUREMENT
●
Setting Tilt Correction by Soft Key
To enable you to select tilt ON/OFF function. setting is not memorized after power is OFF.
[Example] Setting X,Y Tilt OFF
Operating procedure
Option
Display
1
Press [F4] key to get the function page 2.
[F4]
2
Press [F1](TILT) key.
In case ON is already selected, the display shows
tilt correction value.
[F1]
3
Press [F3](OFF) key.
[F3]
4
Press [ESC] key.
[ESC]
●
The setting mode performed here will not be memorized after powering OFF. To set TILT correction in
the initialized setting ( it is memorized after powering OFF), see Section 6.4.3“Vertical and Horizontal
Angle Tilt correction ( Tilt ON/OFF)” .
V : 90°10'20"
HR: 120°30'40"
0SET HOLD HSET P1
↓
TILT REP V% P2
↓
TILT SENSOR:[XY-ON]
X:-0°00'25"
Y: 0°00'20"
X-ON XY-ON OFF ---
TILT SENSOR: [OFF]
X-ON XY-ON OFF ---
V : 90°10'20"
HR: 120°30'40"
TILT REP V% P2
↓