background image

Microprocessor

:

SH7750S

Processor speed

:

162MHz 

MIPS

:

300MIPS

Operating system

:

Microsoft  Windows CE Ver. 3.0

Memory

:

32MB / 64MB RAM with flash ROM 2MB
32MB / 64MB / 128MB flash disk (Internal)

RAM retention

:

Li-rechargeable battery(65mAh)-backed for data when main battery not 
present 

Display

:

320x240 QVGA (monochrome) 
STN Reflective type
Temperature compensation

Illumination

:

Front light (CCFL)

Key board

:

56 key keyboard with separate alpha and numeric

Pen touch screen

:

Resistive touch screen/passive Pen digitization

Interface

:

RS-232C serial (6 pin)
RS-232C serial (D-sub 9)
USB(1.1)
Compact flash : Type I / Type ll (Based on Compact Flash)

External power

:

8.4V to 20V Available run charge (11V to 20V)

Audio

:

Sealed Speaker (mono) Sealed Microphone

Durability

:

IP66 (Based on the standard IEC 60529) 

*1)

*1) With the connector and slot covers

Operation
Temperature

:

-20°C to +50°C (-4°F to +122°F) 

Storage
Temperature

:

-30°C to +60°C (-22°F to +140°F) 

Protection against 
shock

:

Designed to protect falling on the hard surface from 1.0m above the ground.

EMC

:

CE, FCC 

Integral heater

:

Auto/Off

Battery BT-59Q

:

Li-ion rechargeable Battery   7.4V 1800mAh
(This battery does not contain mercury.)

Rating

:

8 hours

Charging time

:

Approx. 3.0 hours with BC-29
Approx. 6.0 hours with AD-9B/7C

Dimensions

:

255x130x61.5(mm)

Weight

:

0.8kg(with battery)

Battery Installation

Remove the handstrap from the FC-1000.

Using a coin, loosen the screw on the battery cover.

Remove the battery cover.

Install the battery pack.

Using a coin, install the battery cover. Tighten the screw 

firmly.

STORAGE PRECAUTIONS

SPECIFICATIONS

Always clean the instrument after use.
Use a clean cloth moistened with neutral detergent or water.
Never use an abrasive cleaner, ether, thinner benzene, or other solvents.
Always make sure the instrument is completely dry before storing. Dry any moisture with a soft,
clean cloth.

FC-1000    64837 90030     0303 (4D) 

TRANSMITTION DATA TO THE PC

Turn on the PC and the FC-1000.

Connect the FC-1000 to your PC with the interface cable A-21 as shown below.

The FC-1000 will prompt “Connecting to Host”.

The PC will prompt for setting up a partnership or setting up as a guest. 

When working as a guest, you can browse the files on your FC-1000 and copy or move 
information. Choose [ESC] to set up as a guest.
Once a connection has been established, the icon will appear on your PC.

Click on [Explore] to move or copy files between the PC and the FC-1000.

Serial 
COM1

PC

Interface cable A-21

FC-1000

COM port

Reference software for Connectivity

See the WEB page as follows.
www.microsoft.com/mobile/pocketpc/downloads/activesync35.asp

The FC-1000 has an external CF slot, so the files in the FC-1000 can move to your PC through the CF
card.

CF slot
(TYPE I/

CF card and 
PCMCIA adapter

PC with PCMCIA slot

FC-1000

PREPARATION FOR USE

There are two ways to charge the battery as follows.
Battery Charging (Using BC-29)

Install the battery on the BC-29.

Plug the power cord in an outlet.(AC-120V or 230V) Charging is 

completed after approximately 3 hours.

The Charge LED of BC-29 will indicate charging status;

Red ON

: Charging.

Green ON

: Charging completed.

Red Flashing

: Charging error.

On Solid

: Pre charging.

Battery Charging (Using AD-9B/7C)

After installing the battery, plug the connector of AD-9B/7C in the FC-

1000.

Plug the AD-9B/7C in an outlet. Then the run charge LED will light.

Charging is completed after approximately 6 hours.
The display can be turned on or off by the power key.

The Run Charge LED of FC-1000 will indicate charging status;

Red ON

: Charging.

Green ON

: Charging completed.

Red Flashing

: Charging error.

Be sure to turn the FC-1000 power OFF when removing the battery, since
the data will be lost.

Battery

Adjusting Touch Screen

Turn on the instrument after hard-reset or tap [Start] [Setting] [Control Panel] [Stylus].

Using a stylus pen, touch the center of the cross hairs. (5 points)

After touching all corsairs, press [ENT] key.

(Use an accessory stylus pen to touch a screen. Do not use neither a ball-point pen nor pencil.

Stylus pen

Corsairs

Touch Screen

Note

1)Recharging should take place in a room with an ambient temperature range of +10°C to +40°C (+50°F to +104°F).
2)The battery source will discharge when stored and should be checked before using with instrument .
3)Be sure to charge a stored battery source every 15 days and store in a place at 30°C and below when it will not 

used for a long period. If you allow the battery to be completely discharged, it will have an effect on the overall 
performance for proper charging in the future.

4)The charger may develop heat while charging, there is no problem of it.
5)If charging is done at high temperature, charging time of the battery may take longer.

Interface Cable

CF Card

BC-29

BT-59Q

AD-9B/7C

RUN Charge LED

Connector

Charge LED

TOPCON CORPORATION

75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan  
Phone: 3-3558-2520  Fax: 3-3960-4214   www.topcon.co.jp

TOPCON POSITIONING SYSTEMS, INC.

5758 West Las Positas Blvd., Pleasanton, CA 94588, U.S.A.
Phone: 925-460-1300 Fax: 925-460-1315 www.topcon.com

TOPCON CALIFORNIA

3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329

TOPCON MIDWEST

891 Busse Road, Elk Grove Village, IL 60007, U.S.A.
Phone: 847-734-1700 Fax: 847-734-1712

TOPCON EUROPE B.V.

Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com

TOPCON BELGIUM

Preenakker 8, 1785 Merchtem, Belgium
Phone: 052-37.45.48 Fax: 052-37.45.79 

TOPCON DEUTSCHLAND G.m.b.H.

Weidkamp 180, 45356 Essen, GERMANY
Phone: 0201-8619-100 Fax: 0201-8619-111  [email protected]
www.topcon.de

TOPCON S.A.R.L. 

89, Rue de Paris, 92585 Clichy, Cedex, France.
Phone: 33-1-41069490  Fax: 33-1-47390251  [email protected] 

TOPCON ESPAÑA S.A.

HEAD OFFICE

Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern Barcelona, Spain.
Phone: 93-473-4057 Fax: 93-473-3932  www.topconesp.com

MADRID OFFICE

Avenida Burgos, 16E, 1∞28036, Madrid, Spain.
Phone: 91-302-4129 Fax: 91-383-3890

TOPCON SCANDINAVIA A. B. 

Neongatan 2 S-43151 Mölndal, SWEDEN
Phone: 031-7109200 Fax: 031-7109249

TOPCON (GREATBRITAIN) LTD.

HEAD OFFICE

Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
[email protected]   [email protected]

TOPCON SOUTH ASIA PTE. LTD.

Blk 192 Pandan Loop, Pantech Industrial Complex, #07-01, Singapore 128381
Phone: 62780222 Fax: 62733540  www.topcon.com.sg

TOPCON AUSTRALIA PTY. LTD.

408 Victoria Road, Gladesville, NSW 2111, Australia
Phone: 02-9817-4666 Fax: 02-9817-4654  www.topcon.com.au

TOPCON INSTRUMENTS (THAILAND) CO., LTD.

77/162 Sinn Sathorn Tower, 37th Fl.,
Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 662-440-1152~7  Fax: 662-440-1158

TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.

Lot 226 Jalan Negara 2, Pusat Bandar Taman Melawati, 
Taman Melawati, 53100, Kuala Lumpur, Malaysia.
Phone: 03-41079801  Fax: 03-41079796

TOPCON KOREA CORPORATION

2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.
Phone: 82-2-2055-0321 Fax: 82-2-2055-0319  www.topcon.co.kr

TOPCON OPTICAL (H.K.) LIMITED

2/F., Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road, 
Shatin, N.T., Hong Kong
Phone: 2690-1328  Fax: 2690-2221  www.topcon.com.hk

TOPCON CORPORATION BEIJING OFFICE

Room No. 962 Poly Plaza Building, 14 Dongzhimen Nandajie,
Dongcheng District, Beijing, 100027, China
Phone: 10-6501-4191~2  Fax: 10-6501-4190

TOPCON CORPORATION BEIRUT OFFICE

P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON. 
Phone: 961-4-523525/961-4-523526  Fax: 961-4-521119 

TOPCON CORPORATION DUBAI OFFICE

P.O.Box 28595, 102, Al Naily Bldg., 245 Abu Hail Road, Deira,Dubai,UAE
Phone: 971-4-2696511  Fax: 971-4-2695272 

Back-Up Battery

•The back-up battery built in FC-1000 needs to be charged approximately 24hrs. before using it for the first time after

purchase. Connect the AD-9B/7C or install the fully charged BT-59Q battery to FC-1000 in order to charge the
back-up battery.

•Leaving FC-1000 without the BT-59Q battery or AD-9B/7C for more than an hour will cause the memorized data to

be lost, due to low voltage of the back-up battery. Connect the BT-59Q battery or AD-9B/7C as soon as possible.

Note: 

The instrument may develop heat while charging, there is no problem of it.

EMC NOTICE

FCC conditions

This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference. 
(2) This device must accept any interference received, including 

interference that may cause undesired operation.

Отзывы: