D4008 – EN EZ 2810 Operators Manual
32
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
PRINT FORMAT
2304
AUTO
, WTONLY,
DOWNLD, DT+TM,
ID+TM, IDWTTM,
BATCH1, PRTAC1,
PRTAC2, PRTAC3,
PRWTRC,
WTRCTM,3200-A, 3200-
B, SCLABC
Select alternate & comma (CSV) formats.
PRINT
ACCUMULATION 2305
Shows a running total of weights printed.
REMOTE
DISPLAY
2401
EZ2,
EZ3MUX,
COG,NONE
Select type of remote display
REMOTE
TERMINAL
2402
ON/
OFF
Sends display data to serial remote terminal interface
BAR GRAPH
MODE
2411
OFF,
RIGHT
, LEFT,
MIDOUT, MID IN
Selects output for a bar graph display when used with an RD4000
Remote Display
WEIGHT GRAPH
2412
ON
/OFF
Enables graph to be used with weight when used with a RD4000
Remote Display.
BAR WEIGHT
2413
12000
Enter the full scale gross weight for the bar graph display.
PRESET GRAPH 2414
ON
/OFF
Enables graph to be used with presets when used with an RD4000
Remote Display.
TIMER GRAPH
2415
ON
/OFF
Enables graph to be used with timers when used with an RD4000
Remote Display.
MENU 3 - MOTION & WEIGHT
DISPLAY COUNT
3001
.01,.02,.05,.1,.2,.5,1,2,5,
1
0
,20, 50,100
Select display count size of weigh values.
CAPACITY
3002
40,000
Enter MAXIMUM weight measurable on scale.
WM1 ADJUST 1
3003
10
thru
19
Increase this number to smoothing weighing
WM1 ADJUST 2
3004
0 thru 9
0=off. Use value less than WMA1-1 for quick response weight.
WM1 ADJUST 3
3005
4000
Enter the weight to active quick response weight
Default-10% of scale capacity
WM2 ADJUST 1
3006
30
thru 39
Increase this number to smoothing weighing
WM2 ADJUST 2
3007
10
thru 19
10=off. Use value less than WMA2-1 for quick response weight.
WM2 ADJUST 3
3008
4000
Enter the weight to active quick response weight
Default-10% of scale capacity
MOTION
3101
ON/
OFF
ON = Motion arrow flashes with unstable weight. Prevents: Print,
Zero, Tare, Advance
MOTION
WEIGHT
3102
0
Enter weight used to detect motion. 0=Standard detection
MENU 4 - PRESET, ALARM, and TIMER
PRE ALARM
METHOD
4001
WEIGHT,
PERCENT
Select weight or percentage method for pre-alarm