background image

2

DISPLAY FOR SAFE USE

In order to encourage the safe use of products and prevent any danger to the operator or others or
damage to property, important warnings are put on the products and inserted into the instruction manuals.
We suggest that everyone understand the meaning of the following displays and icons before reading the
"SAFETY PRECAUTIONS" and text.

DISPLAY

ICON

Display

Meaning

WARNING

Improper handling or ignoring this display may lead to the

serious injury or death.

CAUTION

Improper handling or ignoring this display may cause personal

injury or physical damage.

Injury refers to cuts, bruises, burns, electric shock, etc.

Physical damage refers to extensive damage to a building(s), peripheral equipment and/or
furniture.

Icon

Meaning

This icon indicates Prohibition.
Specific contents are shown with words or an illustration located next
to the 

 icon.

This icon indicates Mandatory Action.
Specific contents are shown with words or an illustration located next
to the 

 icon.

This icon indicates Hazard Alert (Warning).
Specific contents are shown with words or an illustration located next
to the 

 icon.

The appliance is employing a "hospital grade" attachment plugs.
Grounding reliability can only achieved when the equipment is
connected to an equivalent receptacle marked "hospital Grade" or
"hospital Only".

Содержание AIT-16

Страница 1: ...INSTRUCTION MANUAL ADJUSTABLE INSTRUMENT TABLE AIT 16...

Страница 2: ...l at hand for future reference Storage method 1 Environmental conditions Temperature 10 40 C Humidity 35 85 Air pressure 700 1060 hPa 2 When storing the table adhere to the following conditions 1 Do n...

Страница 3: ...njury or physical damage Injury refers to cuts bruises burns electric shock etc Physical damage refers to extensive damage to a building s peripheral equipment and or furniture Icon Meaning This icon...

Страница 4: ...and remove the power plug from the outlet If you keep operating the table without solving this problem a fire may occur Ask your dealer to repair it 10 CAUTION Icons Prevention Item Page Don t incline...

Страница 5: ...equency energy within standard and may affect other devices in vicinity If you have found out by turning on off the instrument that it affects other devices it is recommended to change the direction k...

Страница 6: ...n the back cover CAUTION Make sure the table fixation bolts are tightened securely When a bolt becomes loose the tabletop may come off causing the loaded equipment to fall off and cause an injury CAUT...

Страница 7: ...ATURE AND FUNCTIONS 7 STANDARD ACCESSORIES 8 HOW TO USE ASSEMBLY PROCEDURE 9 INSTALLATION OF DEVICE 10 OPERATION 10 TROUBLE SHOOTING TROUBLE SHOOTING GUIDE 11 REFERENCE MATERIALS OPTIONAL ACCESSORIES...

Страница 8: ...on its top Base The leg unit is attached to it by means of the center column Spare receptacle Used to supply power for a loaded device Main switch This is the power switch of the main unit Caster Use...

Страница 9: ...ntheses show the quantity If any of the standard accessories are missing contact your local TOPCON office Instruction manual 1 Makeup button 2 Fuse 2 5A 125V 2 10A 125V Hexagonal socket bolt M6 20 Wit...

Страница 10: ...place Set the tabletop in place so that the 50mm hole for arranging the cord is at the opposite side of the up and down switch To attach the tabletop use the four accessory M6 hexagonal socket bolts w...

Страница 11: ...switch according to the patient s posture The table moves up and down by pressing the up and down switch WARNING If smoke comes from this adjustable instrument table immediately turn off the power sw...

Страница 12: ...over of this man ual Check list WARNING Do not disassemble modify or repair this adjustable instrument table You may receive an electric shock Ask your dealer to repair it CAUTION To prevent electric...

Страница 13: ...FORMANCE 1 Performance Dimensions of main unit Type A 525 W 490 D 660 880 H mm Weight 23kg Weight of main unit Allowable load weight 50kg Power supply voltage and frequency 120Vac 50 60Hz Power supply...

Страница 14: ...to or stacked with other equipment IF adjacent or stacked use is necessary the EQUIPMENT or SYSTEM should be observed to verify nor mal operation in the configuration in which it will be used Guidanc...

Страница 15: ...ferential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and Voltage...

Страница 16: ...mit ters as determined by an electromag netic site survey a should be less than the compliance level in each fre quency range b Interference may occur in the vicinity of equipment marked with the foll...

Страница 17: ...eparation distance according to frequency of transmitter m 150kHz to 80MHz d 1 2 80MHz to 800MHz d 1 2 800MHz to 2 5GHz d 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12...

Страница 18: ...turn off the power 2 Do not store the adjustable instrument table in a dusty place Replacement of fuse Make sure that the power is OFF and the power cord is removed from the outlet 1 Turn the fuse hol...

Страница 19: ...ble according to your local government s laws regarding dispo sition and recycling Part name Type Consumable part Fuse 5A 125V Bel Fuse Inc Fuse 10A 125V Bel Fuse Inc GSA 125V 5A N GSA 125V 10A N CAUT...

Страница 20: ...8381 Phone 62780222 Fax 62733540 www topcon com sg TOPCON SOUTH ASIA PTE LTD Excella Business Park Block C 1st Floor Jalan Ampang Putra Taman Ampang Hillir 55100 Kuala Lumpur MALAYSIA Phone 03 4270119...

Отзывы: