5.

 

BMS Management system   

Over current protection: 

Status indicator light is red when charging current is greater 

than 10A.   
 

Low-voltage protection:

 When the battery voltage is lower than 9.2V, BMS 

automatically close all output function, status indicator light turns red. You need to turn off 
the switch, and then turn on the switch to make the product recover to normal.   
 

Over-voltage protection:

 When the battery voltage exceeds 12.5V, BMS automatically 

close all input.   
 

Overload protection: 

When output power or start power of device is too large, BMS 

automatically turn off the device, status indicator light turns red. You need to turn off the 
switch, and then turn on the switch to make the product recover to normal.   
 

Short circuit protection:

 When AC output protection, BMS automatically turn off the 

device, until the next boot after 5 seconds delay, the AC output start up automatically; When 
DC output protection, BMS automatically turn off the device, green light turns red, until the 
next boot after 15 seconds delay, the DC output start up manually (Note: make sure the load 
is without short circuit, and then turn on the product).   
 

Overheating protection: 

When internal temperature is over 149

  or 65

, BMS 

automatically turn off the device, status indicator light turns red. You need to turn off the 
switch, and then turn on the switch to make the product recover to normal.   

6.

 

Warning 

Please read the following content carefully before using this product, because it will damage 
this product and the related electrical equipment if operated improperly or used this product 
with unmatched electricity equipment. Please check whether the power and voltage of 
electric equipment is suitable for this product before using. 

* Please use required voltage or the built-in adaptor of this product to charge when you 

adopt AC charge. It is forbidden to charge by unmatched voltage or make a short circuit 
when charging; 

* It is forbidden to touch the internal metal of OUTPUT or make the short

circuit of output 

artificially; 

* It is forbidden to connect the AC output of this product with grid; 
* Do not shower or immerse the product into water; It should be placed in a cool and dry 

environment when not in use; 

* It is forbidden to put this product into fire, heater or hot heat source; 
* It is prohibited to knock or throw the product; 
* It is prohibited to use the product in places of strong static electricity and strong magnetic. 

Otherwise, it will damage the safety protection device of the product; 

* This product has perfect protection function, but please be careful when used and try to 

avoid wrong connections and short circuit operation to prevent accidental damage; 

Содержание TB1250N-T500W

Страница 1: ...OPBAND NEW ENERGY CO LTD Address Topband Industrial Park Liyuan Industrial Zone Shiyan Bao an Shenzhen China 518108 Web www topband com cn Registered Dengzhaowei Customer Checked Customer model Approv...

Страница 2: ...V00 Page 2 of 6 Specification revisal record REV Date Contents Revised Remarks V00 2017 06 2 8 First issue DZW...

Страница 3: ...ould be used for household and office appliances electrical equipment in public place and rescue stations including television audio electronic games lighting fans laptops and mobile phone etc 2 Produ...

Страница 4: ...of solar panel AC adapter charge port When this product is charged by AC charge please connect the special AC adapter which comes with the product to this port to charge the product DC 12V car cigaret...

Страница 5: ...e wave output frequency 50Hz 220V 60Hz 110V 4 6 DC12V Output Output Voltage DC12V 5 Max Output Current Imax 8A 4 7 USB DC5V Output Output Voltage DC5V 5 Max Output Current Imax 2A 4 8 Overheating prot...

Страница 6: ...urn off the device status indicator light turns red You need to turn off the switch and then turn on the switch to make the product recover to normal 6 Warning Please read the following content carefu...

Страница 7: ...time Please charge the equipment periodically within three months to prevent the battery aging The AC output of this product is standard 220V 110V sine wave voltage it must be treated carefully and a...

Страница 8: ...e it will cause battery heat get into fire or lose some function and reduce the life When battery run out of power please charge your battery timely 15day Please use the matched or suggested charger f...

Страница 9: ...od of time without being used In addition if the various usage conditions such as charge discharge ambient temperature etc are not maintained within the specified ranges the life expectancy of the bat...