Topaz F-FL/70/50K/KN/BZ-67 Скачать руководство пользователя страница 2

Items:

F-FL/70/50K/KN/BZ-67

F-FL/70/50K/SF/BZ-67

F-FL/70/50K/TR/BZ-67

www.topaz-usa.com

925 Waverly Ave  •  Holtsville, NY 11742  •  800-666-2852  •  Fax: 631-758-8026

INSTALLATION INSTRUCTIONS FOR LED MEDIUM FLOOD LIGHTS

F-FL/90/50K/KN/BZ-67

F-FL/90/50K/SF/BZ-67

F-FL/90/50K/TR/BZ-67

Before starting make sure that the power is disconnected.

Unpack fixture and ensure that there are no damaged parts.

If using Yoke / Trunnion Mount:

Secure fixture to flat mounting surface using 2 bolts.

Aim fixture by loosening the 2 bolts on the U-Bracket to the desired angle.  Tighten down both bolts.

Insert power cord into junction box. Ensure there is a water tight seal going into the junction box.

Wire end of cord to power supply as seen below.

If using Knuckle Mount:

Attach fixture to outdoor box cover, routing the fixture wires into the junction box.  Connect fixture cables as seen below.
Black to Black, White to White, Green to Green.

Aim fixture by loosening the bolt on the arm, and reposition to the desired angle.  Tighten the bolt.

If using Slip Fitter:

For slip fitter installation pass the wires from the slip fitter into the tenon post top.

Make connections as seen below. Black to Black, White to White, and Green to Green.

The fixture can be aimed using the tilting motion of the slip fitter and the rotating motion of the slip fitter on the tenon.

The slip fitter can be tilted by loosening the securing screw and tilting the fixture up or down.

Once the desired angle is achieved tighten back the securing screw.

The slip fitter is secured to the tenon by tightening the 2 grub screws on the side.

120-277VAC

UNIVERSAL VOLTAGE

Отзывы: