Items:
F-FL/70/50K/KN/BZ-67
F-FL/70/50K/SF/BZ-67
F-FL/70/50K/TR/BZ-67
www.topaz-usa.com
925 Waverly Ave • Holtsville, NY 11742 • 800-666-2852 • Fax: 631-758-8026
INSTALLATION INSTRUCTIONS FOR LED MEDIUM FLOOD LIGHTS
F-FL/90/50K/KN/BZ-67
F-FL/90/50K/SF/BZ-67
F-FL/90/50K/TR/BZ-67
•
Before starting make sure that the power is disconnected.
•
Unpack fixture and ensure that there are no damaged parts.
•
If using Yoke / Trunnion Mount:
•
Secure fixture to flat mounting surface using 2 bolts.
•
Aim fixture by loosening the 2 bolts on the U-Bracket to the desired angle. Tighten down both bolts.
•
Insert power cord into junction box. Ensure there is a water tight seal going into the junction box.
•
Wire end of cord to power supply as seen below.
•
If using Knuckle Mount:
•
Attach fixture to outdoor box cover, routing the fixture wires into the junction box. Connect fixture cables as seen below.
Black to Black, White to White, Green to Green.
•
Aim fixture by loosening the bolt on the arm, and reposition to the desired angle. Tighten the bolt.
•
If using Slip Fitter:
•
For slip fitter installation pass the wires from the slip fitter into the tenon post top.
•
Make connections as seen below. Black to Black, White to White, and Green to Green.
•
The fixture can be aimed using the tilting motion of the slip fitter and the rotating motion of the slip fitter on the tenon.
•
The slip fitter can be tilted by loosening the securing screw and tilting the fixture up or down.
•
Once the desired angle is achieved tighten back the securing screw.
•
The slip fitter is secured to the tenon by tightening the 2 grub screws on the side.
120-277VAC
UNIVERSAL VOLTAGE