![Top Auto RR2200 Dual Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/top-auto/rr2200-dual/rr2200-dual_manual-for-use-and-maintenance_1127547067.webp)
14/03/2017
Vers. 1.0
67
Image 52
– Dehidrating Filter
11.2 Dehydrating Filter Replacement
Replace the dehydrating filter after
130 kg
of recovered gas or at least every
2 years
even if the station is used
occasionally.
Activate the filter emptying procedure before dismounting it (contact the technical assistance)
Disconnect the station from the power supply
Open the rear/front panel of the station
Close the taps of the internal bottle
Slowly unscrew the filter
Assemble the new filter (according to its direction)
WARNING
DO
NOT
DISCHARGE
THE
FILTER
IN
THE
ENVIRONMENT
BUT
DISPOSE
OF
IT
AS
A
SPECIAL
WASTE
ACCORDING
TO
THE
LAWS
IN
FORCE.
12 Information on RESIDUAL RISKS
The residual risks remaining, in spite of the protective measures integrated in the machine's
design and the complementary measures of protection, are:
1)
OVERTURNING OF THE MACHINE
If the operator does not respect the obligation, written on this manual, to accompany the machine while it is
being moved and brake it during use, he/she may suffer damages for crushing due to the overturning of the
machine.
2)
CASTING OF REFRIGERANT GAS
If the operator does not respect the obligation, written on this manual, regarding the correct connection of the
machine to the vehicle, by closing the bottle's taps during the operations of extraordinary maintenance and
by using protective gloves and goggles, he/she may suffer damages due to the casting of refrigerant gas.
3)
SHEARING
If the operator does not respect the obligation, written on this manual, of disconnecting the machine from the
electric power supply before entering the machine, he/she may suffer damages due to contact with the vanes
of the electric fan.
4)
SUFFOCATING DUE TO REFRIGERANT GAS
If the operator does not respect the obligation, written on this manual, regarding the connection of the
machine to the vehicle, by closing the bottle's taps during the operations of extraordinary maintenance, by
using the machine only in ventilated environments, and by carrying out the correct maintenance of the
machine, he/she may suffer damage due to the inhalation of refrigerant gas.
5)
DIRECT CONTACT WITH ELEMENTS IN TENSION (LIVE)
If the operator does not respect the obligation, written on this manual, of disconnecting the machine from the
electric power supply before entering the machine, he/she may suffer damages due to direct contact with
elements in tension (live).
6)
INDIRECT CONTACT
If the machine is connected to an unprotected socket, regarding indirect contacts as stated in the laws in
force in the country of use, as written on this manual, he/she who comes in indirect contact with parts in
tension (live) may suffer damages.
Final notes
The images in this document are given as an indication.
Top Auto Srl reserves the right to change the models described in this publication at any time and without notice for
commercial or technical reasons.