38
8 Control functions
8.1 Engine switch
1
(1) Engine switch in “STOP” position
The ignition switch is switched off. The engine will not start.
2
(2) Engine switch in “ON” position
The ignition switch is switched on. The engine can be started.
8.2 Oil warning light (yellow)
If the oil level falls below the minimum level, the oil warning light (1) will turn on and the engine will stop automatically.
If the engine is not refilled with oil, it will not start.
Tip: If the engine stalls or fails to start, switch the engine switch to “ON” and then pull the pull starter.
If the oil warning light flashes for a few seconds, this indicates that there is insufficient engine oil. Refill the engine with
oil, and then restart the engine.
8.3 Overload indicator (red)
The overload indicator (3) lights up when the system detects an overload in a connected electrical device, when the
inverter control unit overheats, or when the AC output voltage increases. The AC protection function will then be trig-
gered. Power generation will be stopped to protect the generator and all connected electrical devices. The AC indica-
tor light (green) will switch off and the overload indicator (red) will stay on, but the engine will not stop.
If the overload indicator switches on and power generation stops, do the following:
1. Switch off all connected electrical devices and the engine.
2. Decrease the total power of the connected devices to reduce the rated output power.
3. Check for blockages at the cooling air inlet and the control unit. If any blockages are visible, remove them.
4. After checking, restart the engine.
Tips: The overload indicator may light up for a few seconds when you connect electrical devices that require a large
inrush current, such as a compressor or submersible pump. This does not indicate a malfunction.
8.4 AC indicator (green)
The AC indicator (2) switches on when the engine is started and power is being generated.
8.5 DC overload protection
The DC overload protection function automatically switches to “OFF” (2) when an electrical device is connected to the
generator and the output current is higher than the rated power. To use this device again, switch on the DC overload
protection by setting the knob to “ON” (1).
1
(1) “ON”
Direct current is generated.
2
(2) “OFF”
Direct current is not generated.