Operation

a) Button description

Button Function

•  Briefly press this button to turn on the product.
•  Press and hold the button for approx. 2 seconds to turn off the product.

Audio

•  Press this button to activate/deactivate the acoustic signal function. If activated, 

the acoustic signal indicator will appear in the upper part of the display.

•  The acoustic signal will sound for angles of 0°, 45° and 90° (±0.5°).

REF

•  Press this button to determine a reference angle. The letter S will subsequently 

appear in the upper part of the display.

•  Press the button again to deactivate the reference angle function.

CAL

•  Use  this  button  to  calibrate  the  product.  Refer  to  the  next  sub  chapter 

“d) Calibration” for more information.

Unit

•  Press this button to select the desired measuring unit (degree, percent, mm/m, 

IN/FT).

Hold

•  Press this button to freeze the current measurement on the display. The letter H 

will subsequently appear in the upper part of the display.

•  Press the button again to deactivate the Hold function.

b) Conducting measurements

•  Switch on the product.
•  Place the product on the surface under test. The display will show the measured value.
•  Switch off the product after completing the measurement.

c) Automatic power-off

The product will turn off automatically after 3 minutes of inactivity.

d) Calibration

Calibrate the product in case it has been dropped.

•  Place the product on a flat surface with a maximum tilt of 5°. Make sure the display is facing 

you.

•  Press and hold the CAL button.
•  Release the button once the CAL1 indicator appears in the display.
•  Wait for the measured value to be displayed.
•  Rotate the product horizontally by 180°, in order for the rear side to face towards you. Doing 

so, the product must be at the exact same spot as before.

•  Press and hold the CAL button.
•  Release the button once the CAL2 indicator appears in the display.
•  Wait  for  the  CAL2  indicator  to  flash  three  times. After  that,  the  measured  value  will  be 

displayed again.

•  The calibration process is then completed.

The “Err” indicator appearing in the display indicates a malfunction. Turn off the 

product and then repeat the calibration process.
If the malfunction occurs again, place the product on another surface.

Tips and notes

•  When freezing the measurement in the display (Hold function), you can easily convert the 

measured value into another unit by pressing the Unit button.

•  Use the reference angle function to transfer an angle from one object to another. This function 

will set the selected reference angle to zero.

•  When turning the product upside down, the displayed value will be rotated by 180°.

Maintenance and cleaning

•  The product is maintenance-free except for potential battery replacement and occasional 

cleaning.

•  Do not use any abrasive or chemical cleaners.
•  Never submerge the product in water to clean it.
•  To prevent scratch marks, do not apply too much force on the surface during cleaning.
•  Use a dry, clean, soft and lint-free cloth to clean the housing.

Disposal

a) Product

Electronic devices are recyclable waste and must not be disposed of in the household 

waste.
At the end of its service life, dispose of the product in accordance with applicable 

regulatory guidelines.
Remove any inserted (rechargeable) batteries and dispose of them separately from 

the product.

b) (Rechargeable) batteries

You  as  the  end  user  are  required  by  law  (Battery  Ordinance)  to  return  all  used  batteries/

rechargeable batteries. Disposing of them in the household waste is prohibited.

Contaminated (rechargeable) batteries are labeled with this symbol to indicate that 

disposal in the domestic waste is forbidden. The designations for the heavy metals 

involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) 

batteries, e.g. below the trash icon on the left).
Used batteries/rechargeable batteries can be returned to collection points in your 

municipality, our stores or wherever batteries/rechargeable batteries are sold.

You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical data

Power supply ........................................2 x AAA battery (not included)
Accuracy ...............................................0.5 mm/m
 

0.2°

Material .................................................Aluminium, ABS
Operating conditions .............................0 to +40 °C, 0 – 50 % RH
Storage conditions ................................-10 to +50 °C, 0 – 90 % RH
Dimensions (W x H x D) .......................253 x 60 x 27 mm
Weight ..................................................250 g

Содержание 1377557

Страница 1: ...isplay angezeigt Die Spannungsversorgung erfolgt über 2 AAA Batterien nicht enthalten Eine Verwendung ist nur in geschlossenen Räumen also nicht im Freien erlaubt Der Kontakt mit Feuchtigkeit z B im Badezimmer u ä ist unbedingt zu vermeiden Aus Sicherheits und Zulassungsgründen CE dürfen Sie das Produkt nicht umbauen und oder verändern Falls Sie das Produkt für andere Zwecke verwenden als zuvor be...

Страница 2: ...d der Indikator CAL2 auf dem Display erscheint Warten Sie bis der Indikator CAL2 dreimal blinkt Danach erscheint der Messwert erneut Die Kalibrierung ist hiermit abgeschlossen Falls der Indikator Err auf dem Display erscheint ist eine Störung aufgetreten Schalten Sie das Produkt aus und wiederholen Sie die Kalibrierung Falls erneut eine Störung auftritt platzieren Sie das Produkt auf einer anderen...

Страница 3: ...level Operating instructions Safety instructions Read the operating instructions carefully and especially observe the safety information If you do not follow the safety instructions and information on proper handling in theses operating instructions we assume no liability for any resulting personal injury or damage to property Such cases will invalidate the warranty guarantee a Persons Product The...

Страница 4: ...ase the button once the CAL2 indicator appears in the display Wait for the CAL2 indicator to flash three times After that the measured value will be displayed again The calibration process is then completed The Err indicator appearing in the display indicates a malfunction Turn off the product and then repeat the calibration process If the malfunction occurs again place the product on another surf...

Страница 5: ...tation en énergie électrique est fournie via 2 piles de type AAA non comprises L utilisation est seulement autorisée à l intérieur de locaux et est interdite en plein air Impérativement éviter tout contact avec l humidité par ex dans la salle de bains etc Pour des raisons de sécurité et d homologation CE toute transformation et ou modification du produit est interdite Si vous utilisez le produit à...

Страница 6: ...clignote trois fois Ensuite la valeur mesurée apparaît de nouveau L étalonnage est terminé Si l indicateur Err apparaît sur l affichage un dysfonctionnement s est produit Éteignez le produit et répétez l étalonnage Si un dysfonctionnement apparaît de nouveau placez le produit sur une autre surface Conseils et instructions Tandis que la valeur mesurée est gelée sur l affichage fonction de maintien ...

Страница 7: ...om wordt geleverd door 2 AAA batterijen niet meegeleverd Het is alleen bedoeld voor gebruik in afgesloten ruimtes dus gebruik buitenshuis is niet toegestaan Contact met vocht zoals bijv in de badkamer moet te allen tijde vermeden worden In verband met veiligheid en normering CE zijn aanpassingen van en of wijzigingen aan dit product niet toegestaan Indien het product voor andere doeleinden wordt g...

Страница 8: ...indicator CAL2 driemaal heeft geknipperd Daarna wordt de meetwaarde opnieuw getoond Het ijkproces is hiermee voltooid In het geval dat de indicatie Err op het beeldscherm verschijnt is er een storing opgetreden Zet het product uit en herhaal het ijken Als er weer een storing optreedt plaats het product dan op een ander oppervlak Tips en aanwijzingen Terwijl de meetwaarde op het beeldscherm bevrore...

Отзывы: