background image

5

 

Know your power tool.

 Read operator’s manual 

carefully. Learn its applications and limitations, as well 
as the specific potential hazards related to this tool. 
Following this rule will reduce the risk of electric shock, 
fire, or serious injury.

 

Drain tank of moisture after each day’s use.

 

If unit will not be used for a while, it is best to leave drain 
valve open until such time as it is to be used. This will 
allow moisture to completely drain out and help prevent 
corrosion on the inside of tank.

 

Risk of Fire or Explosion.

 Do not spray flammable 

liquid in a confined area. Spray area must be well 
ventilated. Do not smoke while spraying or spray where 
spark or flame is present. Keep compressors as far from 
the spraying area as possible, at least 15 feet from the 
spraying area and all explosive vapors.

 

Risk of Bursting.

 Do not adjust regulator to result 

in output pressure greater than marked maximum 
pressure of attachment. Do not use at pressure greater 
than the rated maximum pressure of this compressor.

 

If connected to a circuit protected by fuses,

 use 

time-delay fuses with this product.

 

To reduce the risk of electric shock,

 do not expose to 

rain. Store indoors.

 

Inspect tank yearly for rust, pin holes, or other 
imperfections that could cause it to become unsafe.

 

Never weld or drill holes in the air tank.

 

Make sure the hose is free of obstructions or snags.

 

Entangled or snarled hoses can cause loss of balance 
or footing and may become damaged.

 

Use the air compressor only for its intended use. Do 
not alter or modify the unit from the original design 
or function.

 

Always be aware that misuse and improper handling 
of this tool can cause injury to yourself and others.

 

Never leave a tool unattended with the air hose 
attached.

 

Do not operate this tool if it does not contain a 
legible warning label.

 

Do not continue to use a tool or hose that leaks air 
or does not function properly.

 

Always disconnect the air supply and power supply

 

before making adjustments, servicing a tool, or when a 
tool is not in use.

 

Do not attempt to pull or carry the air compressor 
by the hose.

 

Your tool may require more air consumption than 
this air compressor is capable of providing.

SPECIFIC SAFETY RULES

 

Always follow all safety rules recommended by the 
manufacturer of your tool, in addition to all safety 
rules for the air compressor. 

Following this rule will 

reduce the risk of serious personal injury.

 

Never direct a jet of compressed air toward people 
or animals. Take care not to blow dust and dirt 
towards yourself or others.

 Following this rule will 

reduce the risk of serious injury.

 

Protect your lungs.

 Wear a face or dust mask if the 

operation is dusty. Following this rule will reduce the 
risk of serious personal injury.

 

Do not use this air compressor to spray chemicals.

 

Your lungs can be damaged by inhaling toxic fumes. A 
respirator may be necessary in dusty environments or 
when spraying paint. Do not carry while painting.

 

Inspect tool cords and hoses periodically and, if 
damaged, have repaired at your nearest Authorized 
Service Center. Constantly stay aware of cord 
location.

 Following this rule will reduce the risk of 

electric shock or fire.

 

Never use an electrical adaptor with this grounded 
plug.

 

Check damaged parts. Before further use of the 
air compressor or air tool, a guard or other part 
that is damaged should be carefully checked to 
determine that it will operate properly and perform 
its intended function. Check for alignment of 
moving parts, binding of moving parts, breakage of 
parts, mounting, and any other conditions that may 
affect its operation. A guard or other part that is 
damaged should be properly repaired or replaced 
by an authorized service center.

 Following this rule 

will reduce the risk of shock, fire or serious injury.

 

Make sure your extension cord is in good 
condition. When using an extension cord, be sure 
to use one heavy enough to carry the current your 
product will draw. A wire gauge size (A.W.G.) of at 
least 14 is recommended for an extension cord 50 
feet or less in length. A cord exceeding 100 feet is 
not recommended. If in doubt, use the next heavier 
gauge. The smaller the gauge number, the heavier 
the cord.

 An undersized cord will cause a drop in line 

voltage resulting in loss of power and overheating.

 

WARNING:

 This product contains one or more 

chemicals known to the State of California to cause 
cancer and birth defects or other reproductive harm. 
Wash hands after handling.

 

Save these instructions.

 Refer to them frequently 

and use them to instruct others who may use this air 
compressor. If you loan someone this tool, load them 
these instructions also.

Содержание TS11OL227

Страница 1: ...4 7 CUSTOMER SERVICE 1 866 242 4298 Thank you for buying a Tool Shop product Your air compressor has been engineered and manufactured to Tool Shop s high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance ...

Страница 2: ...sibility to drain oil lubed units prior to shipment to meet ICC state and local fire regulations Please have your model number and serial number available These can be found on the data label on your product Retain a copy of your receipt with purchase date for reference NOTICE 8 0 3 328 287 2863 9 8 32 2 6 35 2 This tool has many features for making its use more pleasant and enjoyable Safety perfo...

Страница 3: ...n will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the employer and user must ensure that he...

Страница 4: ... qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury GENERAL SAFETY RULES Disconnect power supply open drain valve to decompress tank and allow water to drain and allow air compressor to become cool to the touch before servicing Turn pressure regulator knob fully counter clockwise after shutting off compressor When servicing a tool us...

Страница 5: ...ys follow all safety rules recommended by the manufacturer of your tool in addition to all safety rules for the air compressor Following this rule will reduce the risk of serious personal injury Never direct a jet of compressed air toward people or animals Take care not to blow dust and dirt towards yourself or others Following this rule will reduce the risk of serious injury Protect your lungs We...

Страница 6: ...6 Do not adjust the regulator to result in output pressure greater than the marked maximum pressure of the attachment Do not use at a pressure greater than the rated maximum pressure of this compressor ...

Страница 7: ... WLMIPHW SV E JYPP JEGI WLMIPH LIR RIIHIH I VIGSQQIRH MHI MWMSR 7EJIX 1EWO JSV YWI SZIV I IKPEWWIW SV WXERHEVH WEJIX KPEWWIW MXL WMHI WLMIPHW P E W YWI I I TVSXIGXMSR LMGL MW QEVOIH XS GSQTP MXL 27 62 2 7 8 7 27869 8 327 8LI JSPPS MRK WMKREP SVHW ERH QIERMRKW EVI MRXIRHIH XS I TPEMR XLI PIZIPW SJ VMWO EWWSGMEXIH MXL XLMW TVSHYGX 7 1 30 7 2 0 1 2 2 2 6 62 2 98 32 98 32 RHMGEXIW ER MQQMRIRXP LE EVHS...

Страница 8: ...e plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances Do not modify the plug provided If it will not fit the outlet have the proper outlet installed by a qualified electrician The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If rep...

Страница 9: ...andard Cubic Feet Per Minute A unit of measure of air delivery L min Liter Per Minute A unit of measure of air delivery Tank Pressure Gauge Indicates the pressure in the air tank Thermal Overload Switch Automatically shuts off the compressor if the temperature of the electric motor exceeds a predetermined limit ...

Страница 10: ...M 90 PSI 4 2 SCFM 40 PSI Lubrication Oil Free Gauges one gauge 1 5 in one gauge 2 0 in diameter Input 120 V 60 Hz AC only 13 5 Amps Net Weight only compressor 49 6 lbs Fig 2 PRESSURE REGULATOR KNOB SAFETY VALVE HANDLE TANK WHEEL MANUAL ON OFF SWITCH QUICK COUPLER RUBBER FOOT REGULATOR PRESSURE GAUGE TANK PRESSURE GAUGE DRAIN VALVE ...

Страница 11: ...ings PRESSURE REGULATOR KNOB Use the pressure regulator knob to adjust the amount of air being delivered through the hose REGULATOR PRESSURE GAUGE The current line pressure is displayed on the regulator pressure gauge This pressure can be adjusted by rotating the pressure regulator knob SAFETY VALVE The safety valve is designed to automatically release air if the air receiver pressure exceeds the ...

Страница 12: ...secure it in position Rubber foot packing list Screw 8 mm 2 Washer 2 Rubber Foot 1 Nut 8 mm 2 Mount the wheels as shown in figure 3 Tighten firmly with an open end wrench not included to secure the wheels in position Wheel packing list Screw 10 mm 2 Wheel 2 Nut 10 mm 2 Wheel Plug 2 Fig 3 WHEEL SCREW 10mm NUT 8mm NUT 10mm SCREW 8mm WHEEL PLUG RUBBER FOOT WASHER ...

Страница 13: ...urself and others BREAKING IN THE PUMP See Figure 4 5 Check and tighten all bolts fittings etc Turn the pressure regulator knob fully clockwise to open the air flow Place the switch in the OFF O position and plug in the power cord Open the drain valve completely Turn the air compress ON l and run the air compressor for 10 minutes to break in pump parts Place the switch in the OFF O position Close ...

Страница 14: ... tools to air hose by inserting the male quick connect plug to the quick coupler at the end of the coil hose see Fig 8 Connect the power cord to the power supply Turn the switch ON I Rotate pressure regulator knob to desired line pressure Turning the knob clockwise increases air pressure at the outlet turning counterclockwise reduces air pressure at the outlet NOTE Before connecting or disconnecti...

Страница 15: ...ss of air after releasing the safety valve ring indicates a problem with the safety valve Discontinue use and seek service before continued use of the air compressor OPERATION WARNING Unplug the air compressor and release all air from the tank before servicing Failure to depressurize tank before attempting to remove valve may cause serious personal injury WARNING Do not attempt to tamper with safe...

Страница 16: ... sufficient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating oils etc come in contact with plastic parts Chemical can damage weaken or destroy plastic which may result in serious personal injury Electric tools...

Страница 17: ... and cord length Take compressor to service center Thermal overload protector cuts out repeatedly Low voltage Lack of proper ventilation room temperature too high Wrong gauge wire or length of extension cord Check with voltmeter Move compressor to well ventilated area Check for proper gauge wire and cord length Air receiver pressure drops when compressors shuts off Loose connections fittings tubin...

Страница 18: ...18 REPLACEMENT PARTS LIST PARTS DIAGRAM AIR COMPRESSOR ...

Страница 19: ... 1 114 9011049 WHEEL PIN 2 117 9038408 RUBBER HANDLE 1 127 9270048 RILSAN PIPE 1 15 ft 131 9063200 PRESSURE SWITCH 1 132 9065680 CORD WITH PLUG 1 133 9414765 POWER SWITCH 1 145 9043345 SENDING PIPE 1 500 9038570 SEMIPLASTIC COVER LOWER 1 501 9064788 LOCK CABLE 1 502 9414744 GAUGE 1 503 9038402 WHEEL PLUG 2 504 9064815 WIRING 1 505 9050565 ELBOW 1 506 9050566 CONNECTOR STRAIGHT 1 507 9142803 SCREW ...

Страница 20: ...20 REPLACEMENT PARTS LIST PARTS DIAGRAM PUMP UNIT ...

Страница 21: ...5 BEARING 6203 2Z XL 1 041 C710300 CONROD COVER OL227 1 045 9140211 SEEGER 12 UNI 7435 ROHS 1 046 9038711 FAN OL227 UL 1 062 A650300 GASKET CYLINDER VALVE PLATE SP200 0 8MM 1 064 9415052 GASKET PLATE HEAD OL195SIL 1 078 9040019 SEAL SP200 1 126 9075316 BELT POLY V J4 373 1 600 9411228 SCREW TCEI 6X35 BRN 5931 129 4 601 9103284 SCREW TSEI 6X20 10 9 FST 5933 1 602 9101555 SCREW TCEI 5X16 LEFT R80 RO...

Страница 22: ...ries to persons property or costs This warranty does give you specific legal rights and you may have other rights which vary from state to state Be careful tools are dangerous if improperly used or maintained Seller s employees are not qualified to advise you on the use of this Merchandise Any oral representation s made will not be binding on seller or its employees The rights under this limited w...

Страница 23: ...23 NOTES ...

Страница 24: ...OPERATOR S MANUAL TS11OL227 11 GALLON PORTABLE AIR COMPRESSOR CUSTOMER SERVICE 1 866 242 4298 ...

Отзывы: