Tool Shop 208-2196 Скачать руководство пользователя страница 8

MAINTENANCE

CAUTION: Disconnect tool from the air supply before removing or installing the 
contact tip.

!

r, reassemble in reverse order.

REGULAR MAINTENANCE

 

Clean and inspect the tool daily. Make sure the tool is disconnected from the air 
supply.

 

Blow the tool clean with compressed air and inspect for wear or damage. 
Use  
necessary. DO NOT SOAK tool with cleaning solutions. Such solutions can 
damage internal parts.

 

Inspect the trigger and the safety mechanism to assure the system is complete 
and functional. Check for loose or missing parts, and any parts that may be 
sticking.

 

Keep all the screws tight. Loose screws may cause personal injury

.

 

Place two or three drops of pneumatic oil (included) into the air inlet of the tool 
daily.

ADJUSTING FASTENER DEPTH

The depth to which a fastener is driven is controlled by the depth adjustment (Fig.8).
The depth drive is adjusted to the maximum setting by the factory. 

1.    Fire a fastener into a scrap work piece to check depth.
2.    Using wrench provided, adjust the safety element to achieve desired depth.
3.    Fire another fastener in a scrap work piece and check the depth.
4.    REPEAT AS NECESSARY UNTIL DESIRED DEPTH IS ACHIEVED. The amount 

of air pressure required will vary depending on the size of the setting.

OPERATING PROCEDURES

Fig.8

!

CAUTION: 

   
   
 

 Never attempt to drive a fastener into material that is too hard, at too steep an 
angle, or near the edge of the work piece. The fastener can ricochet causing 
personal injury.

 
 

Carefully check for proper operation of the trigger and safety. 

 

Do not use the tool unless both the trigger and the safety mechanism are 
functional, or if the tool is leaking air or needs any other repair.

8

Содержание 208-2196

Страница 1: ...s manual for safety instructions operating procedures and warranty Put it and the original sales receipt in a safe dry place for future reference For questions about this product Please call 1 866 915...

Страница 2: ...injury Stay alert watch what you are doing and use common sense when operating the tool while tired or under the influence of drugs alcohol or medication A moment of inattention while operating the t...

Страница 3: ...ol as a hammer Never use this tool in a manner that could cause a fastener to be directed toward anything other than the workpiece Never use gasoline or other flammable liquids to clean the tool Never...

Страница 4: ...uring you or others around you Do not carry the tool from place to place holding the trigger Accidental discharge could result Choice of triggering method is important Check manual for triggering opti...

Страница 5: ...ils the pressure delivered to the tool must not exceed 120 PSI The tool could explode which will cause death or serious personal injury Always disconnect air resource a Before making adjustments b Whe...

Страница 6: ...g hoses pipe connectors filters regulators etc must be rated for a minimum working pressure of 150 PSI or 150 of the maximum system pressure whichever is greater Disconnect the tool from the air suppl...

Страница 7: ...en down 2 Position the nail outlet on the workpiece with finger off the trigger 3 Depress the contact mechanism firmly until it is completely depressed then pull the trigger to drive a nail 4 After ea...

Страница 8: ...ADJUSTING FASTENER DEPTH The depth to which a fastener is driven is controlled by the depth adjustment Fig 8 The depth drive is adjusted to the maximum setting by the factory 1 Fire a fastener into a...

Страница 9: ...spring Exhaust port in cylinder head is blocked Replace damaged internal parts Tool skips fasteners Worn bumper or damaged spring Replace bumper or pusher spring Dirt in front plate Clean drive chann...

Страница 10: ...CONICAL SPRING REMOTE CORE SEAL AIR RELEASING BLADE TRIGGER SCREW 5 18 WASHER BUSHING NYLON NUT M5 PIN 3 14 SPRING SPRING PIN 3 16 TRIGGER SAFETY COVER SPRING PIN 3 32 CATCH SUPPORT B SCREW 5 12 CATCH...

Страница 11: ...11 SCHEMATIC DRAWING WARNING Repairs should be made by an authorized repair center Do not open or disassemble this power tool...

Страница 12: ...ility and fitness for a particular purpose Seller shall not be liable for any special incidental or consequential damages The sole exclusive remedy against the seller will be for the replacement of an...

Отзывы: