![Tool-Co BCA350 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/tool-co/bca350/bca350_operating-manual_1126697009.webp)
MANUAL
FAULT DIAGNOSIS
Symptom
Possible Cause
Action
Machine does not run when
switched on
Power cord not properly
fi xed/plugged in
Check that the machine is
properly connected to the
power supply
Power Cord Defective
Have the power cord
checked or replace if
necessary
Main power switch
defective
Have the main power
switched checked and
replace if necessary by a
qualifi ed electrician
Loose electrical connection
inside the electric system
Have the whole electric
system of the machine
checked by a qualifi ed
electrician
Motor defective
Have the motor checked
and replace if necessary by
a qualifi ed technician
Insuffi cient water fl ow
The water pump or water
pipe is blocked
Check and clean water
pump and water pipe
The water pump or water
pipe is faulty or damaged
Check the water pump
and pipe and replace if
necessary by a qualifi ed
technician
Motor stops (power cut out)
Too much pressure exerted
while cutting
Exert less pressure when
cutting
Incorrect specifi cation for
saw blade
Use a saw blade which
corresponds to the material
being cut
Saw has a defective
electrical system
Have the electrical system
checking by a qualifi ed
electrician
Poor machine performance
(low power)
Power cord or extension
cable is too long or the
cable is still wound up
inside the cable drum
Use a power cord or
extension cable of the
rated length, use a cable
drum with cable fully
extended
Power network is
insuffi cient
Observe the electrical
ratings of the machine and
connect it only to a power
network which is rating
compliant
Drive motor no longer runs
at rated RPM
Have the motor checked
and replaced by a qualifi ed
technician if necessary
Pg.6