No.
FUNCTION
EXPLANATION
NOTE
(7) Leak error
[F3]
2. Error display
- [F3] is displayed in time display portion
[F4]
2. Error display
- [F4] will be displayed in time display portion
error
reach desired temperature within 40min.
[F5]
2. Error display
- [F5] will be displayed in time display portion
[F6]
2. Error display
- [F6] will be displayed in time display portion
1. Occurs when positioning function of sychronous motor is not working
2. A fuse blew because of a short circuit.
[F8]
3. Error display
- [F8] will be displayed in time display portion
Door open
1. Before operation or when paused
2
[dr]
- All buttons except POWER button do not function.
2. When door is open during operation
- All load (motor, heater, pump, etc.) will be turned OFF.
MAIN RELAY will be ON.
- All buttons except POWER button will not function.
- The above mode will continue until door close or power OFF.
3. When the door is OPEN and 10 minutes pass, error occurs
and buzzer will sound 5 times. (E1 error)
3
[tS]
2. Display when resistance value is 0
[t0]
- [tS]displayed
- Buzzer will sound 5 times and water disposal
3. Display when resistance value is ∞
- [tO] displayed
- Buzzer will sound 5 times
(10) Water supply valve
1. Occurs when the rotation number of Flow Meter are more than 250.
(in case of water supply in not working)
1. Occurs when the Float Switch (located in the bottom of washer) is closed.
1. Occurs when water temp is above 90 degrees celsius during
heating & sprinkling stroke
(8) High temperature
error
(9) Low temperature
Thermistor
detect function
- When door is opened, [dr] will be displayed with LED.
- Closing the door will be back to before Door open
- When door closes, [dr] is deleted in 88 segment and stroke will
continue after display of remaining time
of current washing.
- [dr] is displayed in the 88 segment and the display shows the
mode that was in progress.
1. Occurs In a heating and sprinkling stroke, when the temperature does not
(11) Sychronous Motor
error
5. After solving the cause, all may be resolved by reconnecting the
power plug.
1. When thermistor's resistance value is 0 (short) or ∞ (disconnection),
it will be detected and will be displayed with the buzzer.
4. Detection of disconnection or short of thermistor will function
when power plug is plugged and when error occurs at this time,
water disposal will not occur.