Recommended Fuse/Breaker Sizing 

 

 

 

 

 

Replacing a lamp module 

 
All TRX lamp modules are interchangeable and can be used in any position on the lightbar. This offers the 
flexibility to configure a lightbar for any mission with perfect balance of flood, spot or dual color amber 
white modules.  
 
With this modular design the replacement of a TRX Lamp couldn’t be easier. Each module is hermetically 
sealed so replacement will not compromise the watertight integrity of the lightbar or void the warranty.  
 
To replace a lamp module simply remove the two lamp clips using a 9/64” hex tool. Unplug the lamp from 
the waterproof connector, plug the new lamp in and reattach the lamp clips.  

 
 
 
 
 
 
 
 
 
 
 
 
 

Maintenance  

 
The best cleaning method is to gently wash the lightbar with a solution of mild soap and lukewarm water, 
using a soft cloth or sponge to loosen any dirt or grime. Thoroughly rinse with clean water to remove any 
cleaner residue and dry the surface with a soft cloth to prevent water spotting. 
 
If using a high-pressure water cleaner and/or a steam cleaner the pressure should not exceed 1,450psi. 
The use of additives to the water and/or steam should also be avoided. 

Important Considerations for Lexan lenses: 

• Never use abrasive or highly alkaline cleaners. 

• Never use aromatic or halogenated solvents like toluene, benzene, gasoline, acetone or carbon 
tetrachloride. 
• Contact with harsh solvents such as methyl ethyl ketone (MEK) or hydrochloric acid can result in 
surface degradation and possible crazing. 
• Never scrub lenses with brushes, steel wool or other abrasive materials.

 

Part Number 

Lamps 

Amp draw 
@13.8Vdc 

Fuse/Breaker Size 

(A)  

TRX-03 

1.3 

TRX-06 

2.1 

TRX-10 

4.2 

10 

Содержание TRX-03

Страница 1: ...IS0614 00 3 15 2016 TOMAR OFF ROAD 2100 W OBISPO AVE GILBERT AZ 85233 800 338 2133 www tomaroff road com Product Manual TRX SERIES LIGHTS TRX 03 TRX 06 TRX 10 ...

Страница 2: ...uns The table below lists the maximum recommended wire run for the power and ground cables in feet Part Number Lamps WIRE GAUGE 18 16 14 12 10 8 TRX 03 1 89 142 225 361 575 914 TRX 06 1 51 81 129 206 328 522 TRX 10 2 25 40 64 103 164 261 Common Switch Wiring Configuration ...

Страница 3: ...nting feet on a flat surface that has sufficient strength to support its weight Using the holes in the mounting brackets as a template mark the location of the mounting holes The mounting holes in the bracket are designed to free fit inch hardware Recommended drill sizes for hardware are 17 64 for clearance holes and 13 64 for tapped holes Note the hole pattern on the foot is on 2 centers For the ...

Страница 4: ...of 5 Dimensions Nominal Length Lamps Dim A Dim B Dim C Dim D Dim E Dim F 3 1 3 41 4 66 5 66 3 00 4 25 3 82 6 1 5 68 6 93 7 93 3 00 4 25 3 82 10 2 10 23 11 48 12 48 3 00 4 25 3 82 Mounting Hole Spacing Outside Dimensions ...

Страница 5: ...ently wash the lightbar with a solution of mild soap and lukewarm water using a soft cloth or sponge to loosen any dirt or grime Thoroughly rinse with clean water to remove any cleaner residue and dry the surface with a soft cloth to prevent water spotting If using a high pressure water cleaner and or a steam cleaner the pressure should not exceed 1 450psi The use of additives to the water and or ...

Отзывы: