Wiring the AC Models 

 

1.

 

Ensure that power is off.  

2.

 

Install conduit to conduit opening and tighten set screw. 

3.

 

Pull field wiring through conduit into enclosure/base. 

4.

 

Remove the threaded dome assembly by twisting it counterclockwise.  

5.

 

Remove the LED light engine assembly by removing 2 screws attaching the metal disk to the case. 

6.

 

Connect the black lead to 120-240VAC 50-60Hz phase (hot) side of the power source and the white 
lead to the common (neutral) side of the AC power source. Connect the green wire to ground.  

7.

 

Select the mode of operation, either flashing or steady burn mode, via either internal dip switch or 
external connections of the blue and yellow wires.  See Table 1 for proper settings and connections.  

Note:  1. Dip switches will override any external wire connections. 
Note:  2. If the blue and yellow wires are not used cut off or cap with a wire nut. 

 

TABLE 1 

Internal Dip Switch Settings for setting modes of operation 

Switch 1 

Switch 2 

Mode 

On 

Off 

Single flash 2 380mS On, 380ms Off 

Off 

On 

Double flash @200mS On, @00mS On, 900mS Off 

On 

On 

Off 

Off 

Off 

Steady Burn PWM @ 66.4% 

External Wire Connections for setting modes of operation 

Yellow 

Blue

 

Mode 

Line 

Neutral

 

Single flash 2 380mS On, 380ms Off 

Neutral 

Line

 

Double flash @200mS On, @00mS On, 900mS Off 

Line 

Line

 

Off 

Neutral 

Neutral

 

Steady Burn PWM @ 66.4% 

Notes: The yellow and blue wires can also be connected to PLC controller for mode 
activation.  For a PLC the input voltage can be either be AC or DC,  but must be greater 
than 100 volts RMS and no more than 240 volts RMS 

8.

 

Replace the LED light engine assembly and attach 2 screws. 

9.

 

Secure the dome to the base of the beacon. 

10.

 

Connect power to the beacon and test it for proper operation 

 
 
Wiring 24 VAC/VDC Models (4375L-24)

 

1.

 

Ensure that power is off. 

2.

 

Install conduit to conduit opening and tighten set screw. 

3.

 

Pull field wiring (including external mode operation wiring, if applicable) through conduit into 
enclosure/base. 

4.

 

Remove the threaded dome assembly by twisting it counterclockwise. 

5.

 

Remove the LED light engine assembly by removing 2 screws attaching the metal disk to the case. 

6.

 

Connect the black lead to 12-30VAC 50-60Hz phase (hot) or 12-30VDC positive DC side of the 
AC/DC power source and the white lead to the common (neutral) side or negative DC side of the 
AC/DC power source. Connect the green wire to ground. 

7.

 

Select the mode of operation, either flashing or steady burn mode, via either internal dip switch or 
external connections of the blue and yellow wires.  See Table 2 for proper switch settings and wire 
connections.

 

Содержание 4375

Страница 1: ...ted below are some other important safety instructions and precaution you should follow Read and understand all instructions before installing or operating this equipment Do not connect this device to the system when the power is turned on After installation ensure that all screws and thread joints are properly tightened After installation test the system regularly to ensure that it is operating p...

Страница 2: ... Neutral Single flash 2 380mS On 380ms Off Neutral Line Double flash 200mS On 00mS On 900mS Off Line Line Off Neutral Neutral Steady Burn PWM 66 4 Notes The yellow and blue wires can also be connected to PLC controller for mode activation For a PLC the input voltage can be either be AC or DC but must be greater than 100 volts RMS and no more than 240 volts RMS 8 Replace the LED light engine assemb...

Страница 3: ...l Wire Connections for setting modes of operation Yellow Blue Mode Line Neutral Single flash 2 380mS On 380ms Off Neutral Line Double flash 200mS On 00mS On 900mS Off Line Line Off Neutral Neutral Steady Burn PWM 66 4 Notes yellow and blue wires can also be connected to PLC controller for mode activation For a PLC the input voltage can be either be AC or DC but must be greater than 10 volts RMS an...

Страница 4: ...R DANGER HIGH VOLTAGE Should the light fail to operate check to see that the proper voltage is reaching the unit If the unit still fails to operate replace the light engine To replace a lens or light engine switch power off and wait 5 minutes before removing lens WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 WARNING EXPLOSION HAZARD DO NOT DISCON...