Tomar 4375 Скачать руководство пользователя страница 1

IS0802-00 
11-08-18

 

 

 

       

 

 
 
 

INSTALLATION, OPERATION  
AND MAINTENANCE DATA SHEET 

FOR - MODEL 4375 LED BEACONS 

 

FOR CLASS I, DIV. 2, GROUPS ABCD 
CLASS II, DIV 2 GROUPS F & G 
HAZARDOUS LOCATIONS 
 
 
 
 
 
 

SAFETY MESSAGE TO INSTALLERS, USERS, AND MAINTENANCE PERSONNEL 

 

It is important to follow all instructions shipped with this product. This device is to be installed by a trained 
installer who is thoroughly familiar with the national electrical code and local codes as well. 
The selection of the mounting location for the device, its controls and the routing of the wiring is to be 
accomplished under the direction of the facilities engineer. In addition, listed below are some other 
important safety instructions and precaution you should follow: 
 

• Read and understand all instructions before installing or operating this equipment. 
• Do not connect this device to the system when the power is turned on. 
• After installation, ensure that all screws and thread joints are properly tightened. 
• After installation, test the system regularly to ensure that it is operating properly. 
• After installation and testing is complete, provide a copy of this instruction sheet to all operating  

 
 
 
Wiring the Beacon 

 

The Model 4375 Series strobe Beacon should be installed per the NEC or CEC, STATE and LOCAL CODES, using 
a suitable wiring system for the specific hazardous location. Alternate installation locations and/or 
orientations should only be performed with the approval of the authority having jurisdiction.  
 
 

Содержание 4375

Страница 1: ...ted below are some other important safety instructions and precaution you should follow Read and understand all instructions before installing or operating this equipment Do not connect this device to the system when the power is turned on After installation ensure that all screws and thread joints are properly tightened After installation test the system regularly to ensure that it is operating p...

Страница 2: ... Neutral Single flash 2 380mS On 380ms Off Neutral Line Double flash 200mS On 00mS On 900mS Off Line Line Off Neutral Neutral Steady Burn PWM 66 4 Notes The yellow and blue wires can also be connected to PLC controller for mode activation For a PLC the input voltage can be either be AC or DC but must be greater than 100 volts RMS and no more than 240 volts RMS 8 Replace the LED light engine assemb...

Страница 3: ...l Wire Connections for setting modes of operation Yellow Blue Mode Line Neutral Single flash 2 380mS On 380ms Off Neutral Line Double flash 200mS On 00mS On 900mS Off Line Line Off Neutral Neutral Steady Burn PWM 66 4 Notes yellow and blue wires can also be connected to PLC controller for mode activation For a PLC the input voltage can be either be AC or DC but must be greater than 10 volts RMS an...

Страница 4: ...R DANGER HIGH VOLTAGE Should the light fail to operate check to see that the proper voltage is reaching the unit If the unit still fails to operate replace the light engine To replace a lens or light engine switch power off and wait 5 minutes before removing lens WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 WARNING EXPLOSION HAZARD DO NOT DISCON...