PROBLEMS AND SOLUTIONS
First check the following before submitting the air conditioner for repair.
Problem
Possible cause
Solution
The appliance does not switch
on when pressing the on/off key.
The indicator light on the water tank flashes and the water
tank is full.
Empty the water tank.
The room temperature is lower
than the set temperature.
Set the temperature once more.
The appliance does not cool sufficiently.
Not all doors and windows are closed.
Make sure that all doors and windows are closed.
There are heat sources that are active in the room.
Remove the heat sources or switch them off if possible.
The temperature is set too high.
Set the temperature once more.
The air inlet is blocked.
Clean the air inlet grille.
The appliance makes a lot of noise.
The surface on which the appliance is placed is not level of
flat enough.
Place the appliance on a flat surface, level if possible.
The noise is caused by the flowing refrigerant liquid within
the air conditioner.
This is normal.
The appliance does not respond to the remote control
The appliance has been switched on via the control panel
on the appliance itself.
The remote control has not been activated.
Press the on/off button on the remote control to activate it.
The appliance does not switch on for a period of 3 minutes
after it has been switched on.
The internal safety system of the compressor prevents the
appliance from being switched on until 3 minutes have
passed since it was switched off.
This delay is normal and the appliance will function normally
after the 3 minutes have passed
Error code P1
The water tank is full.
Empty the water tank.
Error code E0 EEPROM
Technical defect
Contact the Tomado service department.
Error code E1
Sensor for room temperature defective.
Contact the Tomado service department.
Error code E2
Evaporator sensor defective.
Contact the Tomado service department.
Error code E3
Condenser sensor defective.
Contact the Tomado service department.
Error code E4
Operating panel defective.
Contact the Tomado service department.
EN - 24
TECHNICAL SPECIFICATIONS
Type number
TMA9001B
Voltage
220-240Volt ~50Hz
Connected load
1200 Watt
Cooling capacity*
9000Btu/h (2.6kW)
EE Class*
A
EER*
2.6
Power consumption kW
1
Power consumption Standby W
0.5
Current consumption nom. A
4.35 kW
Air displacement max. m
3
/h
295
Dehumidification max. ** L/h
2.26
Suitable for m
3
80
Refrigerant / GWP type/gr
R-290 / 3 /170 g.
Thermostat range °C
17 - 35
Fan speeds
2
Max. noise level dB(A)
63 dB(A)
Dimensions (hxwxd)
703 x 355 x 345 mm
Nett weight
24.7 kg
Protection class
IPX0
Remote control
yes