or other place where easy to operate. Use 3M glue fixation or glass glue fixation to settle it
on the wall.
Installation Of Control Wire: there are two connection cables on the controller, put the 4 pin
cable connected with the controller aviation plug(Refer to figure 4).
Caution
: The temperature wire should
NOT
be parallel to or intersect with the power wire.
Caution
: The temperature sensor should
NOT
be installed on the side of the wall which is behind
the door when the door is opened.
i. Water Inlet
First connect the water magnetizer (if applicable) to the water inlet solenoid valve. Then please
use a 1/2’’ flexible stainless steel hose to connect the other side of the water magnetizer and the
water supply pipeline. Do not connect to metal water supply pipeline directly because which
may damage the water inlet valve.
Attention
: Only use cold water supply.
ii. Drain Outlet
Please use 1/2’’ copper pipe or stainless steel pipe to connect the drain outlet and the drain
pipeline of the house. The drain pipeline should be installed with small angle so as to help
residual water in the steam generator flow to the drain pipe.
Attention:
Don’t use locking pliers to over tight the drain pipe connection. Just make sure it
without leakage under Teflon tape sealing. The water come out from the steam generator will
over 100
℃
. Don’t use the plastic pipe/acrylic pipe/FRP pipe or other similar material pipe.
iii. Steam outlet
Use copper or stainless steel pipe to connect the steam head and the steam outlet pipe of the
generator. The pipe should be less than 3 meters long and minimize the number of elbows,
otherwise heat isolating methods should be implemented.
For steam generator, steam outlet is 1/2’’, please use
AT LEAST
1/2’’ steam pipe, must be
stainless steel pipe or copper pipe.
Attention:
Please
MUST
choose right diameter pipe size, as if the pipe size is smaller than our
instruction, it may cause the steam generator internal pressure to increase suddenly which may
damage the steam generator and have safety risks.
6.3. Installation of electrical
Cautions
All circuits should be installed by licensed electricians and conform to local and national codes.
Power supply must be cut off before installation, maintenance and repair. Press the on/off